Endress+Hauser TT412 iTHERM ModuLine Welded thermowell

SKU: 4695814-1-1035-312
In Stock

  • Application: Hygienic, Aseptic Processes
  • Design: iTHERM QuickNeck
  • Material: 316L Stainless Steel
  • Pressure: Up to 40 bar

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Category:
Brand:

Description

Endress+Hauser TT412: Hygienic Temperature Excellence

The Endress+Hauser TT412: Hygienic Temperature Excellence is a masterfully engineered thermowell designed for the most demanding hygienic and aseptic applications. It’s ideally suited for use in pipes, containers, or tanks, even those with very small immersion lengths, common in industries where cleanliness is paramount. This robust thermowell provides increased protection for the temperature sensor against both physical damage and chemical effects, ensuring reliable and accurate measurements in sensitive processes. Its design prioritizes sensor integrity in critical environments.

Designed for Hygienic and Aseptic Spaces

The TT412 is precisely designed for hygienic and aseptic spaces, making it an indispensable component in the Food & Beverages and Life Sciences industries. These sectors require the highest standards of cleanliness to prevent contamination and ensure product safety. The TT412’s design minimizes areas where product can accumulate, adhering to strict hygienic guidelines. Its specialized construction supports optimal process hygiene, a critical factor for maintaining product quality and regulatory compliance in sensitive production environments.

Ideal for Regular Recalibration Needs

A standout feature, the TT412 is ideal for regular recalibration needs. It allows for the simple and tool-free replacement of the thermometer insert while the process remains closed. This innovative “iTHERM QuickNeck” design is a game-changer for operations that require frequent calibration checks, as it significantly reduces downtime and maintenance costs. The ability to quickly and easily swap out the sensor without disrupting the process flow ensures continuous operation and accurate temperature monitoring, a key benefit for efficiency.

Robust Protection for Temperature Sensor

Providing robust protection for the temperature sensor, the TT412 shields it from harsh physical and chemical environments. This enhanced protection is vital for maintaining the accuracy and longevity of the sensor, especially in aggressive media or high-pressure systems up to 40 bar (580 psi). The careful selection of materials, such as 316L for medium contact, further reinforces its resilience. This ensures consistent and reliable temperature readings, crucial for process control and product quality.

Common Hygienic Process Connections Available

The TT412 supports common hygienic process connections available, ensuring broad compatibility and easy integration into existing systems. This includes weld-in adaptors, clamp connections (acc. to ISO2852), threads (acc. to ISO 228 for Liquiphant adaptor APV Inline), Varivent, and state-of-the-art Tee and Elbow thermowells. These diverse options facilitate seamless installation across various pipeline configurations, minimizing installation complexities. The wide array of connections makes it incredibly versatile, adapting to specific needs.

International Certifications for Uncompromised Quality

Adhering to international certifications for uncompromised quality, the TT412 meets stringent hygiene standards such as 3-A®, EHEDG, ASME BPE, and FDA. It also boasts a TSE Certificate of Suitability, underscoring its suitability for sensitive applications. These certifications are a testament to its superior hygienic design, guaranteeing that the thermowell prevents contamination and can be thoroughly cleaned. This compliance is essential for industries operating under strict regulatory frameworks, ensuring product safety and integrity.

TPT24: Your Trusted Global Supplier

When it comes to purchasing the Endress+Hauser TT412, TPT24: your trusted global supplier, stands as the undisputed leader. As the world’s premier online store for industrial instrumentation, tpt24 ensures that every TT412 unit comes with an ironclad guarantee of authenticity and unparalleled quality. We are committed to delivering your critical equipment securely and promptly, to any country across the globe. Choose tpt24 for reliable service, genuine products, and worldwide accessibility.

Fast Response Time, Optimal Performance

The TT412 boasts a fast response time, optimal performance thanks to its reduced tips with thin walls. This design feature allows for rapid heat transfer, enabling the sensor to quickly detect and respond to temperature changes. Combined with various thermowell root diameters (1/4″, 3/8″, 1/2″) and wetted part finishing options (<30 μinch, <15 μinch electropolished), it ensures precise and immediate temperature readings. Its impressive temperature range from -200 to 650 °C (-328 to 1,202 °F) further solidifies its versatility.

Specifications

  • Measuring principle

    Fabricated Thermowell

  • Characteristic / Application

    imperial style
    hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
    hygienic process connections
    iTHERM QuickNeck for easy and cost saving recalibration

  • Head connection

    iTHERM QuickNeck
    NPT1/2

  • Maximum standard immersion length

    48″ (1.219 mm)

  • Process connection

    weld in adaptor
    clamp connections acc. to ISO2852
    thread acc. to ISO 228 for liquiphant adaptor APV Inline
    Varivent
    Tee and elbow thermowells DIN11865

  • Thermowell root diameter

    1/4″ (6,35 mm)
    3/8″ (9,525 mm)
    1/2″ (12,7mm)

  • Medium contact material

    316L

  • Wetted part finishing (Ra)

    < 30 μinch (0,76 μm)
    < 15 µinch(0,38 μm)
    < 15 μinch (0,38 µm) electropolished

  • Tip shape

    straight
    reduced

  • Temperature range

    -200…650 °C (-328…1.202 °F)

  • Max. process pressure (static)

    40 bar (580 psi)

  • Max. process pressure at 400 °C

    depends on process connection

Data Sheet

Download Data Sheet Of: Endress+Hauser TT412 iTHERM ModuLine Welded thermowell