Fluke 1587 FC Insulation Multimeter

SKU: 4695814-1-3
In Stock

  • 2-in-1 Insulation, DMM
  • Insulation tests 50V-1000V
  • VFD low-pass filter
  • CAT III/IV safety rated

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+800) 1234 5678 90 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Category:
Brand:

Description

In today’s intricate industrial and commercial landscapes, electrical systems are the very lifelines of operations, powering everything from machinery and control systems to entire building infrastructures. Maintaining the health and ensuring the safety of these complex electrical networks demands specialized tools that can perform a variety of diagnostic and preventative tasks. Traditionally, technicians might rely on multiple instruments: a dedicated insulation resistance tester to assess the integrity of wiring and motor windings, and a separate digital multimeter (DMM) for general electrical measurements like voltage, current, and resistance. This approach, while effective, can be cumbersome, slow down troubleshooting processes, and increase the likelihood of misplacing equipment or making errors due to tool switching. Recognizing this critical need for streamlined efficiency and enhanced diagnostic capability, the Fluke 1587 FC True-RMS Megohmmeter/Insulation Resistance Tester emerges as a groundbreaking 2-in-1 instrument. It masterfully combines the precise functionality of a high-quality insulation tester with the versatility of a full-featured, true-RMS digital multimeter into a single, compact, and highly portable handheld unit. This ingenious integration provides maximum versatility for both comprehensive troubleshooting of immediate electrical issues and proactive preventative maintenance programs designed to avert costly failures before they occur. It empowers electrical professionals to carry out a broader range of tests with a single, dependable device, optimizing their workflow and enhancing their ability to maintain complex systems.

Precise Insulation Testing for System Health

The cornerstone of preventative electrical maintenance is robust insulation testing, and the Fluke 1587 FC excels in this crucial area. Electrical insulation degrades over time due to factors like moisture, contamination, temperature extremes, and mechanical stress, leading to reduced efficiency, increased energy consumption, and eventually catastrophic equipment failure or even electrical fires. The 1587 FC allows technicians to perform critical insulation tests with a wide range of selectable test voltages: 50 V, 100 V, 250 V, 500 V, and 1000 V. This versatility enables testing on a broad spectrum of electrical equipment, from low-voltage control circuits to high-voltage motors and cables, ensuring comprehensive coverage. The meter can measure insulation resistance from a very sensitive 0.01 MΩ up to an impressive 2 GΩ (gigaohms), providing the precision needed to detect even subtle degradation. Crucially, the 1587 FC supports Polarization Index (PI) and Dielectric Absorption Ratio (DAR) timed ratio tests. These advanced non-destructive tests are vital for assessing the overall condition of insulation and identifying specific issues like moisture ingress or contamination that might not be apparent from a simple spot reading. By providing these essential insulation testing capabilities, the Fluke 1587 FC empowers maintenance professionals to proactively identify potential problems, schedule necessary repairs, and prevent costly unplanned downtime, ultimately extending the lifespan of valuable electrical assets and safeguarding operational continuity by providing insights into the unseen integrity of a system’s electrical pathways, vital for long-term reliability.

Robust Multimeter for Diverse Electrical Diagnostics

Beyond its formidable insulation testing capabilities, the Fluke 1587 FC functions as a fully equipped, true-RMS digital multimeter, ready to handle a vast array of general electrical diagnostics. The inclusion of True-RMS (Root Mean Square) measurement is paramount in today’s electrical environments, where non-linear loads from variable frequency drives (VFDs), LED lighting, and switched-mode power supplies are prevalent. Unlike average-responding meters, True-RMS accurately measures distorted waveforms, providing correct readings essential for proper system analysis and preventing misdiagnoses that could lead to equipment damage or inefficiencies. The 1587 FC measures essential parameters including AC/DC voltage (including sensitive DC millivolts for control circuits), AC/DC milliamps for small current measurements, and foundational parameters like Resistance (Ω) and Continuity for circuit checks and component verification. Further expanding its diagnostic versatility, it measures Capacitance for testing motor capacitors, Diode test for checking semiconductor components, and Temperature with the included K-type thermocouple, vital for thermal troubleshooting. Min/Max recording helps capture intermittent fluctuations, and Frequency (Hz) measurement is useful for verifying motor speeds and control signals. Specifically, the integrated VFD low-pass filter is a critical feature, ensuring accurate voltage measurements on motor drive outputs by eliminating high-frequency noise that can distort readings on standard multimeters. This comprehensive DMM functionality makes the 1587 FC an indispensable tool for everyday electrical troubleshooting and system verification.

Fluke Connect: Wireless Power for Productivity

The Fluke 1587 FC truly steps into the future of electrical diagnostics with its seamless integration into the Fluke Connect® wireless ecosystem. This compatibility allows the meter to wirelessly transmit measurements to a technician’s smartphone or tablet running the free Fluke Connect® Measurements app, revolutionizing how data is captured, analyzed, and shared. A primary benefit is enhanced safety: technicians can monitor their test measurements remotely, keeping themselves out of harm’s way by standing at a safe distance from energized panels or hazardous equipment. This remote monitoring capability significantly reduces the need for constant exposure to potentially dangerous environments. Furthermore, Fluke Connect empowers technicians to prove their job is done right by quickly seeing and sharing measurement results wirelessly with their smartphone. This eliminates the tedious and error-prone process of manually writing down results, saving valuable time and improving data accuracy. The ability to save measurements directly to a phone or the cloud means that data is instantly organized and accessible for later review, reducing paperwork and streamlining administrative tasks. This wireless connectivity transforms the 1587 FC from a mere measurement device into a powerful data acquisition and communication tool, enabling a more efficient, safer, and collaborative approach to electrical maintenance and troubleshooting in the field, allowing professionals to work smarter and faster.

Advanced Diagnostics through Fluke Connect App

The power of Fluke Connect extends beyond basic wireless data transmission, unlocking four powerful new diagnostic functions through the companion app, which significantly enhance the Fluke 1587 FC’s capabilities. Firstly, the app provides PI/DAR timed ratio tests with TrendIt™ graphs. This visual trending of insulation test results over time helps technicians rapidly identify moisture and contaminated insulation problems by showing degradation patterns that might otherwise be missed. This graphical representation makes complex data immediately understandable. Secondly, memory storage through Fluke Connect fundamentally changes data management. By saving all measurements directly to your phone or the cloud, it completely eliminates the need to write down results, drastically reduces errors, and automatically saves data for historical tracking over time. This digital record-keeping is invaluable for long-term asset management. Thirdly, the app allows for Temperature Compensation of insulation resistance readings. Since insulation resistance is highly dependent on temperature, the app can normalize readings to a standard temperature, establishing accurate baselines and relevant historical comparisons that are critical for consistent trending. Finally, with Fluke Connect® Assets (sold separately), the system enables historical tracking and trending of assets to proactively identify insulation degradation over time, allowing real-time decisions to be made in the field regarding maintenance schedules or potential equipment replacement. These app-enhanced functions turn raw data into actionable insights, providing a powerful platform for predictive maintenance and asset reliability management.

Uncompromising Safety in Every Measurement

When working with electrical systems, safety is not merely a feature; it is an absolute prerequisite. The Fluke 1587 FC is designed with multiple layers of user protection to ensure that technicians can perform their critical tasks with confidence. A standout safety feature is live circuit detection, which actively prevents insulation testing if a voltage greater than 30 V is detected on the circuit. This intelligent safeguard eliminates the risk of inadvertently applying a high test voltage to an energized line, protecting both the user and the instrument from potential damage. Furthermore, the meter incorporates auto-discharge of capacitive voltage for added user protection. After performing an insulation test on a capacitive load (like a long cable or motor winding), the meter automatically discharges any stored capacitive energy, preventing dangerous residual voltages that could cause a shock. The Fluke 1587 FC also boasts impressive CAT III 1000 V and CAT IV 600 V safety ratings. These high category ratings signify its robustness against transient overvoltages and its suitability for use in various electrical environments, from inside building distribution panels (CAT III) to the service entrance and utility level (CAT IV), where potential surge energies are highest. This comprehensive approach to safety, from intelligent circuit detection to robust physical design, underscores Fluke’s unwavering commitment to protecting the professionals who rely on their tools in potentially hazardous electrical environments, providing peace of mind during every measurement.

Versatile Applications for Modern Professionals

The combined capabilities of the Fluke 1587 FC make it an incredibly versatile instrument, indispensable for a wide range of specific applications encountered by electrical and maintenance professionals:

  • Motors and Generators: Essential for testing insulation resistance of windings to detect degradation due to age, heat, or moisture, preventing costly motor burnouts.
  • Cables and Wiring: Used to verify the integrity of power and control cables, identifying insulation breakdown before it leads to short circuits or ground faults.
  • Transformers: Critical for assessing the health of transformer insulation, which directly impacts efficiency and lifespan.
  • Switchgear and Circuit Breakers: Allows for insulation checks on internal components to ensure reliable operation and prevent arc flash incidents.
  • Industrial Controls: Useful for troubleshooting control circuits, checking resistance, continuity, and low voltage insulation within complex automation systems.
  • HVAC Systems: The DMM functions are perfect for diagnosing compressors, fans, and control boards, while insulation tests can assess motor windings in large HVAC units.
  • Plant Maintenance Programs: Integrates seamlessly into predictive maintenance (PdM) and preventative maintenance (PM) routines, providing trending data to anticipate failures.
  • Troubleshooting Intermittent Faults: The Min/Max/Average DMM functions and historical tracking via Fluke Connect are invaluable for capturing elusive electrical issues that occur sporadically.
  • Electrical Installations and Commissioning: Used to verify the insulation integrity of new installations before energization and to confirm proper wiring during commissioning.
  • Verifying Repairs: After any electrical repair, insulation testing can confirm the effectiveness of the fix and ensure the system is safe to return to service.

This broad utility makes the 1587 FC a cornerstone tool for any professional dedicated to electrical system health and safety. For professionals globally needing this highly versatile and safe tool, acquiring an authentic Fluke 1587 FC is critical for guaranteed performance and the utmost safety. Recognizing this crucial need for guaranteed quality and authenticity, the online store tpt24 stands out as the best global online store for the Fluke 1587 FC. They ensure the delivery of a genuine product with a guarantee of authenticity and quality to customers in any country, providing the essential tool needed for these critical professional tasks, delivered reliably wherever the job takes you, ensuring that technicians everywhere have access to the authentic equipment.

Your Essential Partner for Electrical Reliability

In conclusion, the Fluke 1587 FC True-RMS Megohmmeter/Insulation Resistance Tester and Multimeter is a groundbreaking, indispensable instrument for electrical and maintenance professionals. Its 2-in-1 design flawlessly integrates a high-performance insulation tester with a full-featured, true-RMS digital multimeter, offering unparalleled versatility for both proactive preventative maintenance and rapid troubleshooting. The comprehensive insulation testing capabilities, including crucial PI/DAR ratio tests across multiple voltages, combine with a wide array of DMM functions like VFD low-pass filtering, capacitance, and temperature measurement, providing a complete diagnostic solution. The true power of the 1587 FC is amplified by its Fluke Connect compatibility, enabling wireless measurements for enhanced safety, streamlined data management, and powerful historical trending and asset tracking via the companion app. Coupled with uncompromising safety features like live circuit detection and auto-discharge of capacitive voltage, and robust CAT III 1000 V / CAT IV 600 V ratings, this meter is built for reliability and user protection in the most demanding environments. With a 3-year warranty and a comprehensive set of included accessories, the Fluke 1587 FC stands as a testament to engineering excellence, empowering technicians to identify hidden problems faster, ensure system longevity, and elevate their work efficiency. For professionals worldwide who demand the best in electrical diagnostic and safety tools, acquiring an authentic Fluke 1587 FC is paramount. The online store tpt24 is unequivocally the premier global online store for this essential product. They are dedicated to providing customers in any country with this indispensable meter, backed by a guarantee of authenticity and quality, ensuring professionals everywhere have access to the genuine Fluke 1587 FC they need to maintain electrical reliability and safety, delivered securely to their location, making tpt24 the trusted global source for this crucial tool.

Specifications

Electrical Specifications
AC voltage measurement
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
DC Voltage Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
6.000 V dc 0.001 V ±(0.09% + 2)
60.00 V dc 0.01 V ±(0.09% + 2)
600.0 V dc 0.1 V ±(0.09% + 2)
1000 V dc 1 V ±(0.09% + 2)
Input impedance 10 MΩ (nominal), <100 pF
Normal mode rejection ratio >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
600.0 mVdc 0.1 mV ±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
¹ 1 kHz bandwidth
Ohms Measurement
Range Resolution Accuracy +(% of Rdg+Counts)¹
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 KΩ ±(0.9% + 2)
6.000 MΩ 0.001 MΩ ±(0.9% + 2)
50.0 MΩ ² 0.01 MΩ ±(1.5% + 3)
Overload protection 1000 V rms or dc
Open circuit test voltage <8.0 V dc
Short circuit current <1.1 mA
¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidity
Diode Test
Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
Accuracy ±(2% + 3)
Continuity Test
Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
Open circuit voltage <8.0 V
Short circuit current 1.0 mA typical
Overload protection 1000 V rms
Response time >1 m sec
Frequency Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)
99.99 Hz 0.01 Hz ±(0.1% + 1)
999.9 Hz 0.1 Hz ±(0.1% + 1)
9.999 kHz 0.001 kHz ±(0.1% + 1)
99.99 kHz 0.01 kHz ±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 mV
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 150.0 mV
DC Trigger Levels¹ to 20 kHz² NA
6.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 1.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 1.5 V
DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
60.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 10.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 36.0 V
DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
600.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
1000.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 300.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale input
Capacitance
Range Resolution Accuracy ±(% of Rdg+Counts)
1000 nF 1 nF ±(1.2% + 2)
10.00 μF 0.01 μF ±(1.2% + 2)
100.0 μF 0.1 μF ±(1.2% ±90 counts)
9999 μF 1 μF ±(1.2% ±90 counts)
Temperature Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)¹
-40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts)
-40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts)
¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
Insulation Specifications
Measurement range 0.01 MΩ to 2 GΩ
Test voltages 50, 100, 250, 500, 1000 V
Test voltage accuracy +20%, -0%
Short-circuit test current 1 mA nominal
Auto discharge Discharge time <0.5 second for C = 1 μF or less
Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load Operable with up to 1 μF load
Output Voltage
50 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 50.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
100 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 60 to 100 MΩ
Resolution 1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
250 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 250 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 250 MΩ
Resolution 1 MΩ
Test current 1 mA @ 250 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
500 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 500 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 500 MΩ
Resolution 1 MΩ
Test current 1 mA @ 500 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 600 MΩ
Resolution 1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 0.6 to 2.0 GΩ
Resolution 100 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)
General Specifications
Maximum voltage applied to any terminal and common 1000 V
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative humidity Noncondensing
0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Radio frequency communication 2.4 GHz ISM Band
Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
Electromagnetic Compatibility
International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Enclosure protection IEC 60529: IP40 (non-operating)
Safety
IEC 61010-1 Pollution Degree 2
IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
Batteries Four AA batteries (IEC LR6)
Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight 550 g (1.2 lb)
Altitude Operating 2000 m
Storage 12,000 m
Over-range capability 110% of range except for capacitance which is 100%
Frequency overload protection <107 V Hz
Fuse protection for mA input 0.44A, 1000 V, IR 10 kA

Data Sheet

Download Data Sheet Of Fluke 1587 FC Insulation Multimeter

Reviews

There are no reviews yet.

Be the first to review “Fluke 1587 FC Insulation Multimeter”

Your email address will not be published. Required fields are marked *