Hanna HI97714 Cyanide Photometer

In Stock

  • Measurement Range: 0.000 to 0.200 mg/L
  • Measurement Method: Pyridine-Pyrazalone Method
  • Light Source: Light Emitting Diode
  • Case Protection: IP67, Floating Case

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Hanna HI97714 Cyanide Photometer: An In-Depth Exploration

The Hanna HI97714 Cyanide Photometer is not merely a measurement device; it is a sophisticated, portable instrument designed to provide unparalleled accuracy and reliability for cyanide testing in water samples. The instrument’s advanced optical system is a testament to Hanna Instruments’ decades of expertise in analytical instrumentation. Unlike older, less efficient photometers that rely on tungsten lamps, the HI97714 utilizes a high-efficiency Light Emitting Diode (LED) as its light source. This design choice is critical, as LEDs consume less power and produce minimal heat, which can otherwise interfere with electronic stability and measurement accuracy. This meter is engineered for field and bench use alike, making it a versatile and indispensable tool for professionals who require precise and consistent results in various environments. Its user-friendly interface and robust design ensure that anyone can operate it effectively, from seasoned laboratory technicians to field-based environmental scientists. The HI97714’s superior performance is a direct result of its innovative features, which collectively streamline the measurement process and guarantee repeatable outcomes with every test.

Innovative Engineering for Flawless Performance

The HI97714’s design incorporates an innovative optical system that stands as a benchmark for modern photometers. This system, composed of a reference detector and a narrow-band interference filter, is sealed from external elements like dust, dirt, and water, protecting the internal components and ensuring long-term reliability. The inclusion of a reference detector is a key advantage, as it automatically compensates for any light source drift caused by power fluctuations or changes in ambient temperature. This ensures a stable light source for both the zero (blank) and sample measurements, which is crucial for maintaining accuracy. The meter also features an exclusive positive-locking system for its cuvette holder. This patented system guarantees that the cuvette is placed in the exact same position every time, eliminating a common source of measurement error and enhancing the reproducibility of results. The combination of these advanced engineering features culminates in an instrument that not only delivers fast and repeatable measurements but also provides peace of mind through its consistent and reliable operation, even in challenging field conditions.

Intuitive Operation for Streamlined Testing

Operating the Hanna HI97714 is a simple and guided experience, thanks to its thoughtfully designed features. The built-in tutorial mode is a particularly valuable asset, providing users with a step-by-step guide through the entire measurement process. This includes instructions for sample preparation, detailing the required reagents and their quantities, and even guiding the user on the proper mixing techniques. This feature is especially beneficial for new users or for those performing less frequent tests, as it eliminates the need to constantly refer to the manual. For added convenience, the meter also features an automatic data logging function, which saves the last 50 measurements. This means that if a measurement is missed or needs to be revisited, it can be easily recalled from the log, providing a complete record of recent tests. The backlit LCD display ensures that readings are clear and visible from any angle, day or night. The meter’s keypad is intuitive, with dedicated keys for power, menu access, and context-sensitive help, making navigation simple and efficient.

Ensuring Accuracy Through Integrated Validation

The integrity of a measurement device is paramount, and the HI97714 addresses this with its exclusive CAL Check™ functionality. This feature provides a stress-free and straightforward method for users to validate the meter’s performance at any time. By simply inserting the certified CAL Check standards, the meter guides the user through the validation process. If the instrument is found to be outside of its accuracy specifications, it can be easily calibrated to the user’s standard, ensuring all future measurements are accurate and reliable. The CAL Check standards are NIST traceable, guaranteeing their quality and reliability. This integrated validation system not only confirms that the photometer is functioning correctly but also allows for a user calibration when needed, providing an extra layer of confidence in the results. This is a crucial feature for applications where precision and regulatory compliance are essential, as it ensures the data generated is always trustworthy.

A Rugged Design Built for the Real World

The HI97714 is engineered to withstand the rigors of field use. Its body is rated to IP67 standards, meaning it is protected from dust and is waterproof. This robust case ensures that the meter can endure knocks, drops, and spills without compromising its performance. In a unique and practical design choice, the meter is also designed to float if it is accidentally dropped in water. The internal optics are sealed, protecting them from outside dust, dirt, and water, which is a common source of damage for field instruments. The meter’s compact and ergonomic design ensures it fits comfortably in the hand for on-the-go testing, while also being stable enough for benchtop use. The use of common 1.5V AA alkaline batteries means that power is always accessible, providing more than 800 measurements without the backlight. This blend of portability, durability, and practical design makes the HI97714 an ideal instrument for demanding environments, where reliability is not just a feature but a necessity.

The Versatility of Cyanide Photometry Applications

Cyanide is a highly toxic chemical, and its accurate measurement is critical across various industries and environmental monitoring programs. The Hanna HI97714 is specifically designed to measure cyanide content in water samples within a range of 0.000 to 0.200 mg/L (ppm), making it suitable for a multitude of applications. One of its primary uses is in environmental testing, where it is vital to monitor water bodies for industrial runoff and potential contamination. The meter’s portability and ease of use are invaluable for field scientists assessing water quality in rivers, lakes, and other natural sources. Additionally, it finds a critical role in industrial processes such as electroplating and mining, where cyanide is used, and strict monitoring is required to ensure compliance with safety and environmental regulations. The HI97714 can also be used in wastewater treatment plants to measure and control cyanide levels before discharge. Its capability to perform measurements on-site allows for immediate decision-making, which can be crucial in preventing environmental damage or mitigating safety risks. The ability to display results in multiple chemical forms, as well as the tutorial mode, makes it an excellent choice for educational and research purposes as well.

Beyond the Instrument: All-Inclusive Accessories

When you acquire the Hanna HI97714, you are not just purchasing a photometer; you are investing in a complete testing solution. Each meter comes supplied with the necessary accessories to get started immediately, including two sample cuvettes with caps and plastic stoppers, three 1.5V AA alkaline batteries, and a comprehensive instruction manual. A meter quality certificate is also included, certifying the instrument’s performance. For those seeking the most economical and comprehensive option, the Cyanide Photometer Kit, model HI97714C, includes additional accessories that enhance the testing experience, such as the CAL Check™ standards. This kit also includes a durable, rugged carrying case, which further protects the instrument during transport and storage, and a specialized cloth for wiping cuvettes, ensuring accurate, scratch-free readings. The availability of these kits and accessories demonstrates Hanna Instruments’ commitment to providing a seamless and professional experience for every user, ensuring they have everything needed for successful and reliable measurements from day one.

Purchase with Confidence from TPT24 Online Store

When it comes to acquiring the Hanna HI97714 Cyanide Photometer, the tpt24 online store stands as the premier destination. As the world’s leading online store for this exceptional product, tpt24 offers a guarantee of authenticity and quality, ensuring you receive a genuine Hanna Instruments product every time. The store’s commitment to customer satisfaction is unparalleled, offering a streamlined purchasing experience and reliable international delivery to any country. This means that no matter where you are, you can access this state-of-the-art photometer and have it delivered directly to your location with complete confidence. The tpt24 online store is dedicated to providing not just a product, but a promise of excellence and reliability, making it the most trusted source for the Hanna HI97714. Their global reach and unwavering commitment to quality make them the undisputed top choice for professionals and enthusiasts worldwide.

Specifications

Feature Specification
Range 0.000 to 0.200 mg/L (as CN¯)

Resolution 0.001 mg/L

Accuracy ±0.005 mg/L ±3% of reading at 25°C

Method Adaptation of the Pyridine-Pyrazalone Method

Light Source Light Emitting Diode

Light Detector Silicon photocell

Cuvette Type Round 24.6 mm diameter (22 mm inside)

Auto-logging 50 readings

Display 128×64 pixel B/W LCD with backlight

Auto-off After 15 minutes of inactivity (30 minutes before a READ measurement)

Battery Type 1.5 V AA Alkaline (3 pcs.)

Battery Life > 800 measurements (without backlight)

Environment 0 to 50°C (32 to 122°F); 0 to 100% RH, non-serviceable

Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0″)

Weight 380 g (13.4 oz.) with batteries

Case Ingress Protection IP67, floating case

Data Sheet

Download Data Sheet Of Hanna HI97714 Cyanide Photometer