Hanna HI98330 GroLine Nutrient Tester
- EC range up to 6.0 mS/cm
- TDS range up to 4200 ppm
- IP67 waterproof floating casing
- Battery life approximately three years
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Precision Conductivity Measurement for Nutrient Solutions
The Hanna HI98330 GroLine Nutrient Tester is engineered for accuracy, reliability, and ease of use in both agricultural and hydroponic environments. Designed to measure Electrical Conductivity (EC) in milliSiemens per centimeter (mS/cm) and Total Dissolved Solids (TDS) in parts per million (ppm), it’s the ideal tool for professionals and enthusiasts who demand consistent monitoring of nutrient concentrations. The built‑in TDS conversion provides precise ppm readings on either the 500 ppm scale or the 700 ppm scale, supporting diverse cultivation needs. With its extended range capability—up to 6.0 mS/cm for EC, 3000 ppm on the 500 ppm scale, and 4200 ppm on the 700 ppm scale—the HI98330’s measurement spectrum makes it suitable for plants with elevated nutrient requirements. This tester eliminates the guesswork often associated with fertilizer solutions, ensuring optimal growth conditions are maintained day after day.
Robust Design Engineered for Lasting Performance
Durability is a defining trait of the Hanna HI98330. The instrument features an IP67 waterproof and floating casing, designed to withstand immersion and resist environmental wear. Graphite electrodes paired with a temperature sensor are housed securely in a composite ABS + PC body, ensuring stable conductivity readings even in challenging agricultural conditions. The rugged build allows the tester to double as a stirring stick, making solutions uniform before taking a measurement. Clearly printed conductivity scales and operational instructions on the tester body mean you can operate without constantly referring to the manual. Additionally, its detachable crown‑shaped cap facilitates easy access for cleaning between electrodes, preventing buildup that could compromise accuracy. Completing the robust profile, the HI98330 carries a 6‑year warranty from Hanna Instruments—cementing its reliability over extended field use.
Seamless User Experience with Automated Functions
Ease of operation is central to the HI98330’s design. The tester is factory calibrated, so no manual calibration is required before use, saving preparation time. Its auto‑on function activates when the probe is placed in nutrient water, while the auto‑off feature conserves battery life by shutting down the device 30 seconds after a stable measurement is obtained. The instrument uses 3 × 1.5V AA alkaline batteries, offering an impressive lifespan of about three years when taking 10 measurements per day. LED feedback simplifies reading results—24 bright blue LED lights illuminate along the conductivity scale for clear visual representation of measurement values. The system also provides a low‑battery warning, prompting replacements before performance is impacted. Designed to operate in environments from 0 °C to 50 °C (32 °F to 122 °F), the GroLine HI98330 serves reliably in a broad spectrum of climate conditions.
Dedicated Applications in Agriculture and Hydroponics
The HI98330 was purpose‑built for hydroponics and soil‑free agriculture, where nutrient levels must be monitored rigorously to maintain plant health. In hydroponic setups, precise EC monitoring ensures nutrient concentrations remain optimal for root absorption, promoting vigorous plant growth and yield consistency. In soil‑based agriculture, the tester assists in verifying fertilizer solution concentration before application, preventing nutrient imbalance that could harm crops or soil microbiota. Its extended EC range accommodates plants with high nutrient demands—such as tomatoes, peppers, cucumbers, and certain ornamental species—ensuring they receive the necessary conductivity levels for thriving growth. In nurseries, greenhouses, and vertical farms, the HI98330 offers quick verification of prepared nutrient solutions, enabling rapid adjustments where deviations occur. For commercial growers, this translates into improved productivity, reduced waste, and optimized resource allocation.
Guaranteed Quality with Global Delivery Service
When sourcing genuine Hanna Instruments products, authenticity matters. tpt24.com is the world’s leading online store for the HI98330 GroLine Nutrient Tester, offering customers an ironclad guarantee of originality and quality. Whether you operate a farm in North America, a hydroponic lab in Europe, or a greenhouse in Asia, tpt24.com delivers worldwide—ensuring you receive your tester swiftly, safely, and verified as genuine. This distinguished store stands out not just for competitive service, but for its commitment to supporting plant cultivation professionals across the globe. Each purchase from tpt24.com arrives with the instrument quality certificate and quick reference guide, just as specified by Hanna Instruments, adding assurance to your investment. With trusted logistics and uncompromising product integrity, tpt24.com makes global acquisition of the HI98330 seamless.
Technical Excellence Through Intelligent Engineering
The HI98330’s internal and external engineering elements work in concert to deliver accurate, stable readings in real time. Graphite sensors resist corrosion and polarization, enhancing measurement stability and extending probe lifespan. Automatic temperature compensation from 5.0 °C to 50.0 °C (41.0 °F to 122.0 °F) ensures readings remain accurate despite varying water temperatures. The carefully designed electrode spacing minimizes interference, while the casing’s ergonomic grip provides handling comfort during stirring and immersion. Visual measurement displays via LEDs allow instant recognition of under‑range and over‑range conditions, helping users quickly identify solution adjustments needed. The device’s extended resolution levels—down to 0.1 mS/cm in lower ranges—make it suitable for both delicate seedlings needing lighter solutions and mature crops requiring stronger mixes.
Maintenance, Cleaning, and Long-Term Care Strategies
Proper care extends the life and accuracy of the HI98330. Routine rinsing after each use removes excess residues from between graphite electrodes, preventing conductivity inconsistencies. For deeper cleaning, the removable crown‑shaped cap allows brushing between electrodes with a soft bristle brush and mild surfactant, followed by thorough rinsing. Batteries should be replaced at the first low‑battery warning—indicated when LED segments show reduced capacity—to prevent the risk of diminished accuracy. The storage protocol recommends keeping the tester dry and clean when not in use, avoiding extreme temperatures or hazardous environments. Given its maintenance simplicity, growers benefit from consistent, dependable performance with minimal upkeep demands. These straightforward procedures, combined with robust design, make the HI98330 a lasting asset in the grower’s toolkit.
Ultimate Tool for Reliable Nutrient Monitoring
From its rugged build to advanced EC/TDS measurement capabilities, the Hanna HI98330 GroLine Nutrient Tester is an indispensable device for serious cultivation professionals. Offering extended range, IP67 waterproof certification, automatic operation functions, and LED‑illuminated measurement feedback, it streamlines nutrient analysis for hydroponics and agriculture. Commercial growers, agricultural researchers, and home horticulturists alike gain from its precision, durability, and intuitive interface. When sourced through tpt24.com, customers secure the assurance of an authentic Hanna product, delivered anywhere in the world with full warranty support. Simply put, the HI98330 empowers you to keep nutrient levels balanced and plants thriving, delivering consistent yields and healthier crops over time.
Specifications
| Specification | Detail |
|---|---|
| Model | HI98330 GroLine Nutrient Tester |
| Measurement Parameters | Electrical Conductivity (EC), Total Dissolved Solids (TDS) |
| EC Range | 0.2 to 6.0 mS/cm |
| EC Resolution | 0.1 mS/cm (0.2–4.0 mS/cm); 0.25 mS/cm (4.0–6.0 mS/cm) |
| EC Accuracy | ±4% of reading ±1 resolution point |
| TDS Range | 100–3000 ppm (500 ppm scale); 140–4200 ppm (700 ppm scale) |
| TDS Resolution | 50 ppm (100–2000 ppm); 125 ppm (2000–3000 ppm); 70 ppm (140–2800 ppm); 175 ppm (2800–4200 ppm) |
| TDS Accuracy | ±4% of reading ±1 resolution point |
| Calibration | Factory calibrated |
| Probe Type | Graphite electrodes in ABS + PC body |
| Temperature Compensation | Automatic from 5.0 to 50.0 °C (41.0 to 122.0 °F) |
| Battery Type | 3 × 1.5V AA alkaline |
| Battery Life | Approximately 3 years (10 measurements/day) |
| Measurement Display | 24 bright blue LEDs |
| Auto Functions | Auto-on when placed in solution; Auto-off 30 seconds after stable measurement |
| Environment | 0 to 50 °C (32.0 to 122.0 °F) |
| Dimensions | 444 mm (17.48 in.) length; Ø 30 mm (1.18 in.) |
| Weight | 265 g (9.3 oz.) with batteries |
| Casing Protection | IP67 waterproof, floating |
| Warranty | 6 years |
| Supplied Accessories | Quick reference guide, instrument quality certificate |