Hanna HI98713-01 ISO Turbidity Portable Meter

In Stock

  • Range: 0.00 to 1000 FNU.
  • Accuracy: ±2% of reading.
  • Light Source: 860 nm infrared LED.
  • Memory: 200 records.

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Unveiling The HI98713’s Technological Excellence

The Hanna HI98713 is a high-precision, portable turbidity meter designed to provide accurate and reliable water quality measurements. It is built with a sophisticated optical system that ensures long-term stability and minimizes stray light and color interference, making it an ideal choice for both field and laboratory applications. The device utilizes an infrared LED light source, which meets and exceeds the ISO 7027 method requirements, providing the added benefit of reducing color interference during measurements. This is a significant advantage over methods using visible light sources, as colored samples do not affect the turbidity reading.

A Comprehensive Suite of Measurement Modes

The HI98713 offers multiple reading modes to suit various measurement needs, including Normal, Continuous, and Signal Averaging. The normal measurement mode is perfect for a quick and single reading, while the continuous mode allows for real-time monitoring of turbidity changes. The signal averaging mode helps to stabilize readings in samples with fluctuating turbidity, ensuring greater accuracy and repeatability. This versatility makes the HI98713 adaptable to a wide range of water quality assessment scenarios, from quick spot-checks in the field to detailed analysis in a laboratory setting.

Seamless Data Management with Fast Tracker™

For advanced field applications, the HI98713 is equipped with the innovative Fast Tracker™ Tag Identification System (T.I.S.). This feature simplifies data collection and management by allowing users to log the time and location of measurements using iButton® tags. Each iButton® tag contains a unique identification code, making it easy to associate specific measurements with their exact sampling points. This system eliminates the need for manual record-keeping, ensuring that data is organized, accurate, and easily traceable.

The Power of ISO-Compliant Calibration

Calibration is a critical aspect of ensuring the accuracy of any measurement device, and the HI98713 excels in this area. It features a powerful calibration function that compensates for variations in light intensity over time. The meter can be calibrated using a two, three, or four-point method with the supplied AMCO AEPA-1 standards. These standards are recognized as a primary standard by the USEPA, are non-toxic, and have a long shelf life. The ability to use user-prepared standards also provides flexibility, allowing for customized calibration points to meet specific application requirements.

Logging and Transferring Your Crucial Data

With the ability to store up to 200 measurements in its internal memory, the HI98713 is a powerful tool for data logging. Users can easily recall stored data at any time for review. For more extensive analysis and long-term storage, the logged data can be transferred to a Windows® compatible PC. The meter is equipped with both USB and RS232 ports, along with the HI92000 software, making data transfer a seamless process. This feature is invaluable for professionals who need to maintain detailed records and generate reports on water quality over time.

Real-World Applications and Significance

The measurement of turbidity is a key parameter in determining the quality of drinking water, as it serves as a competent safeguard against pathogens. In natural water bodies, turbidity measurements are taken to gauge overall water quality and its suitability for aquatic life. Furthermore, turbidity is a crucial parameter in the monitoring and treatment of wastewater, where it is necessary to verify that values are within regulatory standards. The HI98713’s precision and compliance with the ISO 7027 method make it an indispensable tool across these diverse applications, including drinking water treatment plants, environmental monitoring, and wastewater facilities.

A User-Friendly Interface for All

The HI98713 is designed with user convenience in mind. Its Backlit Graphic LCD Display provides a clear and user-friendly interface. All messages and functions are presented in plain text, making them easy to read and understand without the need for complex codes or symbols. This intuitive design minimizes the learning curve and allows users to operate the device efficiently, even with minimal training.

A World-Class Product with Unmatched Support

The HI98713 Precision ISO Turbidity Portable Meter is not just a high-quality instrument; it is a testament to reliable engineering and performance. When you purchase this product, you are investing in a tool that is recognized for its accuracy and durability. To ensure you receive a genuine and quality-assured product, it is recommended to buy from the world’s leading online store for this product, tpt24. We at tpt24 guarantee the authenticity and quality of every HI98713 meter, delivering it to you with full warranty and support, no matter where you are in the world.

Specifications

Specification Details
Range 0.00 to 1000 FNU

Resolution 0.01 (0.00 to 9.99 FNU); 0.1 (10.0 to 99.9 FNU); 1 (100 to 1000 FNU)

Accuracy ±2% of reading plus 0.1 FNU

Range Selection automatic

Repeatability ±1% of reading or 0.01 FNU, whichever is greater

Stray Light <0.1 FNU

IR Detector silicon photocell

Light Source 860 nm infrared LED

Lamp Life greater than 100,000 readings

Method adaptation of ISO 7027, ratio method with 90° and 180° detector

Measuring Mode normal, average, continuous

Turbidity Standards <0.1, 15, 100 and 750 FNU

Calibration two, three or four-point calibration

Log Memory 200 records

Serial Interface USB or RS232

Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing

Power Supply 4 x 1.5V AA alkaline batteries or AC adapter

Dimensions 224 x 87 x 77 mm (8.8 x 3.4 x 3.0 in.)

Weight 512 g (18 oz)

Warranty 2 years