Hanna HI83414-01 EPA Compliant Benchtop Turbidity and Chlorine Meter

In Stock

  • Turbidity range up to 4000 NTU.
  • Chlorine range up to 5.00 mg/L.
  • Log memory for 200 records.
  • USB interface for data transfer.

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

The Ultimate Dual-Parameter Water Quality Meter

The Hanna HI83414-01 is a highly precise benchtop meter that stands as an essential instrument for professionals dedicated to water quality analysis. It represents a sophisticated blend of two critical functions: a nephelometer for measuring turbidity and a photometer for measuring free and total chlorine. This unique combination allows for the simultaneous testing of the most vital parameters in drinking water, which is crucial for ensuring public health and safety. The instrument’s design is a testament to Hanna’s extensive experience, successfully integrating advanced technology with user-centric functionality. Notably, the HI83414-01 not only meets but also surpasses the stringent requirements of the United States Environmental Protection Agency (USEPA) and Standard Methods for turbidity and colorimetric measurements, providing users with a reliable tool for regulatory compliance. The meter is supplied with a complete set of primary AMCO-AEPA-1 turbidity standards and NIST traceable secondary chlorine standards, ensuring that all calibration and performance verification processes are accurate and fully traceable. Its dual-parameter capability and unwavering precision make it an indispensable asset in laboratories, water treatment facilities, and field testing scenarios where accurate and dependable data is paramount. The meticulous engineering behind the HI83414-01 guarantees that it delivers consistent and trustworthy results, time and again, for the most critical drinking water parameters.

Advanced Optical Design for Flawless Measurements

The core of the HI83414-01’s superior performance lies in its state-of-the-art optical system, meticulously engineered to provide accurate, long-term stable results while effectively minimizing common interferences. This system is comprised of a tungsten filament lamp, a scattered light detector positioned at a 90° angle, and a transmitted light detector at 180°. This dual-detector setup is the foundation of the instrument’s ratio nephelometric method, which is highly effective in compensating for fluctuations in the lamp’s intensity and correcting for color interferences in the sample. This innovative approach allows for less frequent calibration and ensures that measurements remain consistently reliable over time. For chlorine measurements, the photometer section utilizes a 525 nm narrow band interference filter, which guarantees accurate and repeatable results by ensuring the correct wavelength is used for the DPD method. To further enhance measurement repeatability, all analyses are performed using 25 mm round cuvettes crafted from special optical glass. The low detection limit of the HI83414-01 is a result of its exceptionally low stray light design, providing highly accurate readings even for low-turbidity samples. By integrating these advanced optical components and sophisticated measuring techniques, the HI83414-01 provides an unparalleled level of precision and reliability for water quality professionals.

Meeting and Exceeding All EPA Requirements

Compliance with regulatory standards is a primary concern for water treatment and quality assurance professionals, and the Hanna HI83414-01 is specifically engineered to meet and exceed these demands. The meter is compliant with EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements. This means the instrument adheres to strict criteria for its operation, including its light source, detector, and sensitivity. The tungsten lamp operates at a specific color temperature, and the distance light travels within the sample tube is carefully controlled. Most importantly, the detector is precisely centered at a 90° angle to the incident light path, with a limited tolerance, and has a spectral peak response between 400 nm and 600 nm. The HI83414-01’s sensitivity allows it to detect a turbidity difference of 0.02 NTU or less in samples with turbidities below 1 unit, fulfilling a key EPA requirement. The instrument also features a specialized EPA compliance reading mode that automatically rounds the final measurement to meet federal reporting requirements, such as rounding to the nearest 0.05 NTU for readings between 0.0 and 1.0 NTU and to the nearest 1 NTU for readings between 10 and 40 NTU. This feature simplifies the reporting process and ensures all data is presented in the required format.

The Gold Standard in Calibration Procedures

Calibration is a critical step in ensuring the accuracy of any analytical instrument, and the HI83414-01 offers a comprehensive and robust calibration system. For turbidity, the meter supports a flexible calibration process that can be performed at two, three, four, or five points, using the supplied standards of <0.1, 15, 100, 750, and 2000 NTU. This flexibility allows users to select a calibration range that best fits their typical measurement needs, with the option to use their own user-prepared standards if the specific calibration points need to be modified. For free and total chlorine, the HI83414-01 includes the powerful CAL Check™ function. This feature allows users to validate the performance of the chlorine colorimeter at any time using exclusive, ready-made, NIST-traceable standards. This provides an instant check on the meter’s accuracy and can be used to perform a one-point calibration. The AMCO AEPA-1 primary turbidity standards supplied with the meter are recognized by the USEPA and are made from uniform styrene divinylbenzene polymer spheres. These non-toxic standards are highly stable and reusable with a long shelf life, ensuring consistent and traceable calibration. All standards come with a Certificate of Analysis (COA) for full traceability, giving users complete confidence in the integrity and reliability of their measurements.

Seamless Functionality for Daily User Operations

Beyond its technical precision, the HI83414-01 is designed with a focus on user-friendliness and operational efficiency. The meter features an easy-to-understand, graphic LCD display with a backlight, making it simple to read measurements and navigate menus in any lighting condition. All on-screen messages are displayed in plain text, eliminating the need for complex codes or symbols and ensuring a smooth user experience. This user interface is further enhanced by a dedicated HELP button, which provides comprehensive contextual help at the press of a button. Clear tutorial messages and directions are available to guide users step-by-step through setup, calibration, and measurement procedures. In addition, acoustic signals provide helpful confirmation and error alerts, guiding the user through the process and helping to prevent mistakes. The inclusion of a unique tutorial mode makes the HI83414-01 an ideal tool for both experienced professionals and new users, as it provides additional information and prompts to guide the user through the analysis process. These thoughtful design elements ensure that even complex analyses can be performed with ease and confidence.

Logging, Transfer, and Data Traceability

In today’s data-driven world, the ability to log, transfer, and trace measurement data is crucial for compliance and quality management. The HI83414-01 excels in this regard, featuring a comprehensive suite of data management capabilities. Its internal memory can store up to 200 measurements, allowing users to log and recall data at their convenience without the need for immediate transfer. For more extensive storage and detailed analysis, the logged data can be easily downloaded to a Windows-compatible PC using the instrument’s USB port and the HI92000 software. This seamless data transfer process ensures that all measurement information is securely archived and readily available for reporting or further analysis. Furthermore, the meter is equipped with complete Good Laboratory Practice (GLP) functions. This powerful feature allows for full traceability of calibration conditions, storing vital information such as the date, time, and calibration points. This GLP data is essential for maintaining accurate records and demonstrating compliance with quality assurance protocols, providing an unbroken chain of traceability for all measurements.

Essential Applications in Water Quality Analysis

The Hanna HI83414-01 is an indispensable tool for a wide range of water quality applications. Turbidity is a key indicator of water clarity and is critical for both drinking water and environmental monitoring. In drinking water treatment plants, controlling turbidity is a competent safeguard against pathogens and is a required measurement by the EPA for surface water sources. In natural water bodies like rivers and lakes, turbidity measurements are taken to assess overall water quality and its suitability for aquatic organisms. Additionally, the HI83414-01 is crucial for monitoring wastewater treatment processes, ensuring that effluent turbidity levels meet regulatory standards before being discharged. The chlorine measurement function is equally vital, as it is used to monitor disinfection levels in drinking water to ensure it is free from harmful microorganisms. The HI83414-01 is an indispensable tool for these critical applications, and for those seeking guaranteed authenticity and quality, the tpt24 online store is the premier global retailer, delivering the product with a quality assurance guarantee to any country. This combination of an essential instrument and a reliable supplier ensures that professionals have the best tools to perform their vital work.

A Complete Summary of Technical Details

The HI83414-01’s robust design is supported by an array of detailed technical specifications that guarantee its performance. The instrument measures turbidity in three different units: NTU, Nephelos, and EBC, and offers both ratio and non-ratio measurement modes, covering an extensive range from 0.00 to 4000 NTU in ratio mode and 0.00 to 40.0 NTU in non-ratio mode. The accuracy for turbidity measurements is impressive, at ±2% of reading plus 0.02 NTU, with repeatability of ±1% of reading or 0.02 NTU, whichever is greater. For free and total chlorine, the meter measures a range from 0.00 to 5.00 mg/L, with a resolution of 0.01 mg/L up to 3.50 mg/L. The instrument’s light source is a long-lasting tungsten filament lamp rated for over 100,000 readings. It features a large 40 x 70 mm graphic LCD display, can store up to 200 records, and connects to a PC via USB. With dimensions of 230 x 200 x 145 mm and a weight of 2.5 kg, it is a robust and reliable benchtop unit designed for professional use in a wide range of environments.

Specifications

Specification Details
SKU HI83414-01
Turbidity Range (Ratio Mode) 0.00 to 9.99, 10.0 to 99.9, 100 to 4000 NTU 0.0 to 99.9, 100 to 26800 Nephelos 0.00 to 9.99, 10.0 to 99.9, 100 to 980 EBC
Turbidity Range (Non-Ratio Mode) 0.00 to 9.99, 10.0 to 40.0 NTU 0.0 to 99.9, 100 to 268 Nephelos 0.00 to 9.80 EBC
Turbidity Resolution (Ratio Mode) 0.01, 0.1, 1 NTU 0.1, 1 Nephelos 0.01, 0.1, 1 EBC
Turbidity Resolution (Non-Ratio Mode) 0.01, 0.1 NTU 0.1, 1 Nephelos 0.01 EBC
Turbidity Accuracy ±2% of reading plus 0.02 NTU ±5% of reading above 1000 NTU
Chlorine Range 0.00 to 5.00 mg/L (ppm)
Chlorine Resolution 0.01 mg/L from 0.00 to 3.50 mg/L 0.10 mg/L above 3.50 mg/L
Chlorine Accuracy ±0.02 mg/L @ 1.00 mg/L
Light Source Tungsten filament lamp
Lamp Life Greater than 100,000 readings
Display 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
Log Memory 200 records
PC Interface USB
Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing
Power Supply 115/130 Vac: 50/60 Hz, auto-off after 15 minutes of non-use
Dimensions 230 x 200 x 145 mm (9.0 x 7.9 x 5.7 in.)
Weight 2.5 kg (88 oz.)

Data Sheet

Download Data Sheet Of Hanna HI83414-01 EPA Compliant Benchtop Turbidity and Chlorine Meter