krohne OPTIFLUX 6100

SKU: 4695814-1-1035-307
In Stock

  • 3A and EHEDG certified
  • Handles liquids with solids
  • Vacuum-resistant PFA liner
  • Intelligent diagnostics for operations

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

The Standard Flowmeter for Hygienic Processes

The OPTIFLUX 6100 is a versatile and highly reliable electromagnetic flowmeter designed specifically for hygienic standard applications in the food and beverage industry. It is the ideal solution for all general flow applications where robust, dependable measurement with mid-range accuracy is sufficient. Unlike meters that offer excessive and often unnecessary features, the OPTIFLUX 6100 provides a cost-effective yet powerful solution. It seamlessly integrates into a wide range of processes, from dosing and filling to continuous monitoring, all while adhering to the most stringent hygienic demands. Its design philosophy is simple: provide a flowmeter that is both highly functional and easy to keep clean and sterile, ensuring product integrity and operational efficiency. The OPTIFLUX 6100 has quickly become the industry’s go-to standard for a reason.

Engineering For Uncompromising Cleanliness and Compliance

The core strength of the OPTIFLUX 6100 lies in its unyielding commitment to hygienic design. The meter is meticulously engineered to be free of any crevices, gaps, or blind spots, which are notorious for harboring bacteria and contaminants. This crevice-free design allows for thorough and complete cleaning, a non-negotiable requirement in the food and beverage industry. Its suitability for a hygienic environment is not just a claim; it is validated by its prestigious certifications. The OPTIFLUX 6100 is 3A and EHEDG certified, the gold standard in hygienic design, guaranteeing that it meets the highest standards for sanitary equipment. It also complies with FDA and EC1935/2004 regulations, providing manufacturers with the ultimate assurance that their processes are safe and their products are protected from contamination.

A Wide Range of Food Applications

The versatility of the OPTIFLUX 6100 makes it an invaluable tool for a vast array of food and beverage applications. It is an excellent choice for dosing and batching of liquids such as milk, juices, and purified water. Its ability to handle solid content up to 10% allows it to excel in more challenging applications like the flow measurement of yogurt with fruit pieces or soups with vegetable pieces, where other meters would clog or fail. The meter’s bi-directional flow measurement capability makes it a versatile tool for processes where liquid is transferred in both directions, such as in filling and emptying tanks. From simple beverage production to more complex food processing, the OPTIFLUX 6100 provides the reliable flow data needed to optimize processes and ensure consistent product quality.

Robustness Through Innovative Material Technology

The construction of the OPTIFLUX 6100 is a testament to thoughtful engineering and material science. It features a robust PFA liner that is reinforced with an embedded stainless steel grid. This innovative design provides a significant advantage, as it makes the meter completely vacuum-resistant. This is a crucial feature for processes that involve negative pressures or aggressive cleaning cycles like Sterilize-in-Place (SIP) where a standard liner could collapse. The meter also incorporates a unique L-shaped gasket that provides a more secure and reliable seal than conventional gaskets. This design prevents the gasket from expanding under pressure, thereby increasing its lifespan and reducing the risk of a leak. This attention to detail ensures that the OPTIFLUX 6100 is not only accurate but also incredibly durable and long-lasting.

Intelligent Diagnostics For Reliable Operations

The OPTIFLUX 6100 is more than just a measurement tool; it is an intelligent instrument that provides valuable insights into both its own performance and the process it is monitoring. The meter is equipped with a suite of diagnostics that can detect issues such as empty pipe conditions, electrode errors, and changes in conductivity and process temperature. This intelligent feedback allows operators to identify and resolve potential problems proactively, preventing costly downtime and product loss. For example, an empty pipe signal can alert operators to a pump failure, while a change in conductivity could indicate a change in the process fluid itself. Furthermore, the meter supports on-site verification with the OPTICHECK service tool, which allows for a quick and accurate check of the meter’s health without having to remove it from the line.

Flexible Installation and Streamlined Integration

The OPTIFLUX 6100 is designed for a perfect fit in any hygienic production environment. It is available with industry-specific installation lengths and a wide variety of hygienic process connections, including clamp, threaded ferrule, and aseptic weld-end fittings. This extensive range of options ensures that the meter can be easily and quickly integrated into new or existing pipelines without the need for custom fabrication. For added flexibility, the OPTIFLUX 6100 is available in both a compact version for tight spaces and a remote version with a wall-mount housing. The remote version also offers an optional stainless steel housing for added durability in harsh washdown environments, ensuring a long and reliable service life.

The Premier Global Source for Excellence

When you are ready to invest in a hygienic flowmeter that sets the standard for reliable performance, you need a partner you can trust. The online store tpt24 is the undisputed premier global retailer for the OPTIFLUX 6100. Tpt24 has built its reputation on a foundation of integrity and commitment to customer satisfaction. Every OPTIFLUX 6100 sold through tpt24 is delivered with a guarantee of authenticity and quality. This assurance means that no matter where you are in the world, you can be completely confident that the product you receive is a genuine, factory-certified instrument. Tpt24’s global reach and dedication to excellence make it the most reliable and trusted partner for procuring this essential piece of equipment.

A Strategic Investment For Long-Term Value

Choosing the OPTIFLUX 6100 is a strategic business decision that offers significant long-term returns. Its unique blend of reliable performance and hygienic design translates directly into reduced operational costs and increased uptime. The meter’s ability to handle solids, its resistance to vacuum and pressure fluctuations, and its intelligent diagnostics all contribute to a healthier bottom line by minimizing product loss and maximizing production efficiency. By providing accurate and consistent measurement data, the OPTIFLUX 6100 empowers businesses to optimize their processes, ensure regulatory compliance, and achieve a high level of product quality. It is a fundamental component for any operation aiming for a perfect balance of performance and value.

Specifications

Specifications

Depending on selected device configuration

General information

Product type Flowmeter
Product family name OPTIFLUX
Product positioning For hygienic standard applications
Measurement principle Electromagnetic
Measured media Liquids

Operating conditions

Process pressure max. 40 barg/
580 psig
Process temperature -40…+140°C/
-40…+284°F

Materials

Liner Perfluoroalkoxy alkane (PFA)

Process connections

Hygienic connections Clamp (DIN 32676): DN25, DN40, DN50, DN65, DN80, DN100, DN125, DN150
Clamp (ISO 2852): 12, 17.2, 25, 38, 51, 63.5, 76.1, 101.6, 114.3, 139.7
Tri-Clamp: ½”, ¾”, 1″, 1 ½”, 2″, 2½”, 3″, 4″, 5″, 6″
Threaded ferrule (DIN 11851): DN10, DN15, DN25, DN40, DN50, DN65, DN80, DN100, DN125, DN150
Flange with groove (DIN 11864-2): DN25, DN40, DN50, DN65, DN80, DN100, DN125, DN150
Threaded ferrule (SMS 1146): 25 mm, 38 mm, 51 mm, 63.5 mm, 76 mm, 101.6 mm
Aseptic weld end fitting (DIN 11850 / EN 10357): DN2.5, DN4, DN6, DN10, DN15, DN25, DN40, DN50, DN65, DN80, DN100, DN125, DN150
Aseptic weld end fitting (ISO 2037): 12, 17.2, 25, 38, 51, 63.5, 76.1, 101.6, 114.3, 139.7

Approvals/Standards

Certificates/Approvals Hygienic FDA, 3A, EHEDG, EC 1935/2004, EC2023/2006

Communication

Analogue outputs 4…20 mA
Discrete outputs Pulse, Frequency, Status
Digital outputs HART®

Data Sheet