Megger EST High voltage discharge rod
- Voltage Range: Up to 150 kV
- Discharge Type: Damped, controlled
- Material: GFK (fiber-glass)
- Safety Feature: Post-charging eliminated
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Megger EST: The Essential Safety Tool
In the demanding world of high-voltage electrical testing and maintenance, safety is paramount. The Megger EST High Voltage Discharge Rod stands as a critical component in ensuring the well-being of personnel and the integrity of electrical systems. Designed specifically for the safe discharging and earthing/grounding of high voltage cables and test units, this sophisticated tool addresses the inherent dangers of residual electrical charge. When conducting dielectric tests or fault location measurements with high DC voltages, cable capacitance can store a significant and perilous amount of energy. The EST discharge rod is engineered to mitigate this risk, providing a reliable and visually confirmable method for eliminating stored energy and preparing equipment for safe handling.
Unwavering Compliance and Versatility Across Voltages
The Megger EST High Voltage Discharge Rod is not just a safety device; it’s a testament to adherence to stringent international safety standards. It complies with EN 50191, EN 61230, and EN 61219, ensuring that its design and performance meet the highest regulatory benchmarks for electrical safety equipment. This commitment to compliance offers peace of mind to professionals operating in diverse industrial and laboratory settings. Furthermore, the product’s versatility is a key advantage, with versions available to handle voltages ranging from 35 kV to an impressive 150 kV. This broad spectrum of options means that irrespective of the specific high-voltage application, there is an EST discharge rod tailored to meet the requirements, offering flexibility and broad applicability across various testing scenarios.
Key Features: Damped Discharge and Post-Charging Elimination
The core functionality of the Megger EST discharge rod lies in its ability to perform a damped discharge, a critical process that safely dissipates stored energy without creating hazardous transients. This is achieved through a strategically integrated discharge resistor within the rod’s tip, which effectively limits the discharge current. This sophisticated design ensures a controlled and gradual release of energy, preventing sudden voltage drops that could damage equipment or endanger personnel. Beyond damped discharge, a standout feature is its capacity to eliminate the post-charging effect. This phenomenon, where a cable retains a residual charge even after initial discharge, is effectively countered by the EST rod, which almost instantly removes the cable charge, significantly enhancing safety by preparing the cable for immediate, visible short-circuiting and earthing.
Robust Construction for Enhanced Safety and Durability
The physical construction of the Megger EST High Voltage Discharge Rod is as impressive as its electrical performance. Built from GFK (fibre-glass strengthened plastic), the rods are inherently robust, lightweight, and offer excellent electrical insulation properties, crucial for high-voltage applications. Each rod is equipped with a comfortable handle and features grip protection with extra-long safety clearance to prevent accidental physical contact with high-voltage components. This meticulous attention to design detail underscores Megger’s commitment to user safety. The availability of six versions, varying in voltage, resistance, and length, further enhances the product’s adaptability, allowing users to select the optimal tool for their specific operational needs and ensuring maximum safety and efficiency in all discharge and earthing procedures.
Applications: Critical in Cable Testing and Fault Location
The applications of the Megger EST High Voltage Discharge Rod are specific and critical, primarily revolving around the safe management of residual charge in high-voltage cables and test setups. It is indispensable during dielectric tests on cables, where high DC voltages are applied, leading to significant charge accumulation. Similarly, in fault location measurements that utilize high DC voltages, the rod is crucial for safely discharging the energized cable after testing is complete. Before any physical interaction with the cable or test unit after a high-voltage application, the EST rod ensures that the stored energy is safely neutralized, making it safe for earthing, short-circuiting, and subsequent maintenance or analysis. Its use is a fundamental step in adhering to strict safety protocols in these high-risk environments.
Operational Excellence and Adherence to Safety Protocols
Using the Megger EST High Voltage Discharge Rod effectively requires adherence to specific operational guidelines to maximize safety and efficiency. It is imperative to ensure the correct number of discharge resistors are screwed together for the selected voltage. Crucially, before using the discharge rod, the earthing cable must be securely connected to a safety or operational earth. Prior to using the hook to earth the cable directly, it is essential to first discharge the cable via the tip of the rod for a couple of seconds to dissipate the primary charge. An important note for users is that these rods are specifically designed for the discharge of high voltage cables within the framework of cable tests. After use, a cooling period of 30 minutes is recommended to prevent thermal overload of the built-in discharge resistors, ensuring the longevity and continued reliability of the device.
The Science Behind Safe Discharge: Formulas and Timeframes
Understanding the principles behind the Megger EST discharge rod’s operation enhances appreciation for its safety features. The energy stored in a charged cable capacitance, representing a dangerous amount of energy, is calculated by the formula: . This highlights why effective discharge is paramount. After a measurement, the cable under test must undergo a damped discharge and a direct, visible earthing. The discharge time () is calculated by the formula: (where R is in M$\Omega$ and C is in F, yielding time in seconds). According to safety guidelines, after 5 – 10 (with a maximum of 5 seconds), the voltage drops to a harmless value. At this point, the cable can be visibly short-circuited using the earthing hook, following established VDE regulations such as DIN EN 50191 / VDE 0104 and DIN EN 61230.
tpt24: Your Global Partner for Megger EST
When it comes to acquiring the Megger EST High Voltage Discharge Rod, tpt24 is the premier online store worldwide. We are committed to providing our customers with not only the finest electrical testing equipment but also an unparalleled purchasing experience. At tpt24, every Megger EST discharge rod is delivered with a guarantee of authenticity and quality. Regardless of your location, tpt24 ensures that this essential safety product reaches you, upholding the highest standards of reliability and customer satisfaction. Our extensive inventory and streamlined global shipping mean that professionals everywhere can access this vital tool, backed by our commitment to product integrity and prompt delivery. Choose tpt24 for your Megger EST needs and experience the assurance of genuine products and exceptional service.
Specifications









Reviews
There are no reviews yet.