Endress+Hauser FQR16 Microwave barrier transceiver Soliwave

SKU: 4695814-1-1035-162
In Stock

  • Range: Max. 20 m
  • Supply: 18V to 30V DC
  • Process Temp: -20°C to +60°C
  • Process Connection: G1″, G1-1/2″, NPT1-1/2″

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Endress+Hauser FQR16: Compact Non-Contact Point Detection

The Endress+Hauser FQR16 is an ultra-compact transceiver crafted for non-contact point level detection of both bulk solids and liquids. It also excels in counting piece goods and detecting objects. The FQR16 is designed for tandem use with the FDR16.

Microwave Barrier for Difficult Installations

This microwave barrier is suited for microwave barrier for difficult installations, employing a non-contact detection method. Its ultra-compact design allows it to be used in areas that are hard to reach or have confined installation conditions, making it remarkably versatile.

External Measurement for Non-Metallic Containers

The FQR16 enables external measurement for non-metallic containers. For containers made of non-metallic materials, it’s possible to measure from the outside, further broadening its application range and utility.

Protecting Against Overflow and Dry Running

The device provides protection protecting against overflow and dry running. Together, the Soliwave FDR16 and FQR16 detect minimum or maximum point levels in powdery to lumpy bulk solids and liquids. They serve as safeguards against overflow and dry running scenarios.

Versatile Use Across Multiple Industries

The FQR16 enables versatile use across multiple industries. It can be deployed in a wide array of industries, including primaries, energy, and food. It’s also well-suited for piece goods counting and object detection tasks.

Independent Measurement of Process Properties

This sensor enables independent measurement of process properties. Benefit from a non-contact measuring principle, ensuring detection that’s largely unaffected by process properties. This adds to its dependability across a wide range of conditions.

TPT24: The Foremost Online Supplier

For the Endress+Hauser FQR16, TPT24: The Foremost Online Supplier stands out. As the world’s top online store for this product, TPT24 guarantees authenticity and top-notch quality. Enjoy prompt delivery to any country worldwide, ensuring you have access to this tech.

Robust Design with Stainless Steel Housing

The FQR16 features a robust design with stainless steel housing. Its design ensures continuous operation that’s both wear-free and maintenance-free. The device will consistently provide dependable performance, minimizing downtime and boosting productivity.

Specifications

  • Measuring principle

    Microwave barrier

  • Characteristic / Application

    Microwave barrier
    Non-contact point level detection
    (min/max, e.g. full and empty detection for overflow
    and dry run protection) for all types of bulk solids
    (from powdery to lumpy) and liquids, also in potentially
    explosive atmospheres (dust Ex).
    Detection, counting, and positioning of objects
    Object detection on conveyor belts

  • Specialities

    Detection range: max. 20 m

  • Supply / Communication

    18 V … 30 V DC,
    Plug M12

  • Ambient temperature

    -20°C … +60°C (-4°F … +140°F)

  • Process temperature

    Non-contact installation: any
    Within installation:
    -20°C … +60°C (-4°F …+140°F)
    With high temperature adapter:
    up to +450°C (+842°F)

  • Process pressure / max. overpressure limit

    Non-contact installation: any
    Within installation:
    0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
    With high pressure adapter:
    up to +21 bar (+305 psi) abs.

  • Min. density of medium

    Solid weight: > 10 g/l

  • Main wetted parts

    Non-contact installation:
    no wetted parts
    Contact installation:
    316L, PTFE

  • Process connection

    ISO228-1: G1″, G1-1/2″
    ASME: NPT1-1/2″

  • Process connection hygienic

    Non-contact installation

  • Communication

    3-wire-DC-PNP,
    2 DC-PNP-outputs

  • Certificates / Approvals

    ATEX, IEC Ex

  • Design approvals

    EN10204-3.1

  • Hygienic approvals

    EG1935/2004

  • Options

    Mounting bracket
    Counternut
    Welding sleeve
    Connection cable
    Connecting cable
    High-pressure adapter
    High-temperature adapter
    Extension for HT adapter
    Mounting flange
    Sight glass fitting
    FAR50, FAR51, FAR52, FAR54

  • Components

    FDR16

  • Application limits

    Solid weight: < 10 g/l