Hanna HI83399-01 Water & Wastewater Multiparameter Photometer and pH meter
- 5 LEDs, ±1 nm accuracy
- 1000-reading logging capacity
- USB-A and micro-USB-B ports
- 3.7 VDC rechargeable battery
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Advanced Multiparameter Solution for Water Quality Analysis
The Hanna HI83399-01 Water & Wastewater Multiparameter Photometer and pH meter is a compact, highly advanced laboratory instrument designed to handle the most demanding water and wastewater quality measurement applications. Equipped to measure 40 essential parameters with 73 distinct methods, it covers multiple ranges and chemical variations to suit industrial, municipal, and research needs. Key digestion parameters such as Chemical Oxygen Demand (COD), Total Nitrogen (TN), and Total Phosphorus (TP) are integrated, enabling operators to monitor nutrient removal processes with unmatched precision. Its innovative optical system, which includes both a focusing lens and reference detector, mitigates errors from light source drift and cuvette imperfections, resulting in performance unmatched in benchtop photometers. The HI83399 doubles as a fully functional pH meter, providing digital pH input capability that allows seamless integration of photometric and pH analysis in a single compact unit, making it ideal for laboratories with limited benchtop space.
Exceptional Optical System Ensures Unparalleled Measurement Accuracy
At the core of the HI83399’s success lies its advanced optical design, incorporating a beam splitter that directs light simultaneously to an absorbance channel and a reference detector. This setup stabilizes readings by compensating for drift due to temperature fluctuations or power variations. The unit employs high-efficiency LEDs, producing superior luminous output with minimal heat generation, thereby eliminating a major source of optical instability common to tungsten-lamp systems. Each wavelength is isolated with high-quality narrow band interference filters (±1 nm accuracy, 95% transmission), ensuring intense, precise light delivery for better measurement stability. Unlike other instruments that require indexing due to cuvette imperfections, the HI83399’s optical path design and large 25 mm cuvette size eliminate this need while improving sensitivity in low-absorbance samples. The addition of a focusing lens ensures maximum light yield to the silicon photodetector, canceling distortions from scratches or imperfections in the cuvette glass.
Comprehensive Applications in Water and Wastewater Testing
The HI83399 is specifically tailored for environmental laboratories, municipal utilities, and industrial facilities that require accurate water quality data for compliance, process optimization, or research. In wastewater plants, it performs COD determinations to assess organic pollutant levels and supports TN and TP measurements to monitor nutrient removal efficiency. For drinking water facilities, its ability to test residual chlorine, metals like aluminum and iron, nutrients such as nitrate and ammonia, and various alkalinity forms ensures thorough quality control. Aquaculture operators benefit from its capability to track pH, dissolved nutrients, and oxidants to maintain optimal aquatic health. Educational institutions use its absorbance mode for teaching the Beer-Lambert Law, while industrial chemists can develop custom concentration vs. absorbance curves for proprietary chemical processes. Its multi-range capabilities mean the same instrument can handle ultra-low, low, medium, and high concentration levels without sacrificing accuracy.
Integrated Digital pH Electrode for Precision Results
Unlike analog pH meters, the HI83399 features a digital pH electrode input with an integrated microchip inside the probe, storing calibration data directly within the electrode. This allows quick hot-swapping between electrodes without recalibrating, saving valuable lab time. In pH measurement mode, the unit supports automatic temperature compensation (ATC) using a thermistor at the tip of the sensing bulb, delivering highly accurate readings over a wide range from -2.00 to 16.00 pH. The instrument supports GLP (Good Laboratory Practice) compliance by logging calibration details such as date, time, buffer values, offset, and slope, ensuring traceability for audits and quality control. Additionally, pH CAL Check features alert the user to potential calibration issues, including contaminated electrodes or incorrect buffers. Whether used for field-simulated wastewater pH analysis or high-precision laboratory measurements, this dual-function system maintains unmatched accuracy and operational convenience.
User-Friendly Data Management and Connectivity Capabilities
The HI83399 offers advanced data logging with memory for up to 1000 readings, encompassing both photometric and pH data. Each reading can be annotated with Sample ID and User ID for streamlined record-keeping. Data export is effortless via the USB-A host port for flash drive transfers or the micro-USB-B port for direct PC connectivity. All files are saved in .CSV format for compatibility with spreadsheet and LIMS software. The backlit 128×64 pixel LCD display ensures clear visibility even in low-light lab environments, with a graphic interface featuring virtual keys and on-screen help to guide users through methods and operations. The built-in reaction timer ensures measurements are taken at precise intervals for consistent, reproducible results across operators. Battery and error status indicators provide real-time feedback, covering warnings like “high zero” in photometry or “check buffer” in pH calibration to prevent compromised data.
Designed for Reliability, Portability and Energy Efficiency
Engineered for lab environments, the HI83399 operates in 0–50°C with up to 95% relative humidity (non-condensing). Its power system includes a 3.7 VDC Lithium-polymer rechargeable battery, delivering over 500 photometric measurements or 50 hours of continuous pH use per charge, alongside a USB power supply option. Compact dimensions (206 × 177 × 97 mm) and a weight of only 1.0 kg make it suitable for mobile laboratory setups or transport between sites. The rugged housing and supplied cuvette cover guard against stray light interference. Supplied accessories include four sample cuvettes and caps, a wiping cloth, USB cables, a power adapter, and an instruction manual—everything ready for immediate operation. With a two-year warranty, the HI83399 provides dependable long-term performance for routine and specialized testing scenarios.
Exclusive Absorbance Mode for Custom Method Development
Beyond preprogrammed methods, the HI83399’s absorbance mode allows scientists to select from five precise wavelengths (420, 466, 525, 575, and 610 nm) to create their own calibration curves. This is ideal for institutions developing new analytical methods, proprietary chemical formulations, or laboratory educational programs. Hanna’s exclusive CAL Check cuvettes are compatible with this mode, enabling light source and detector validation. Users can verify system performance, troubleshoot deviations quickly, and apply custom regression equations for specialized compounds. The mode also empowers educators to teach absorbance principles interactively, demonstrating real-time effects of concentration changes on light transmission. Combined with the photometer’s strong optical stability and high interference filter efficiency, these features open possibilities far beyond standard water and wastewater parameter testing.
Available Worldwide with Guaranteed Authenticity at tpt24.com
The Hanna HI83399-01 is trusted by environmental labs, universities, utilities, and industrial plants worldwide for its exceptional performance and versatility. To ensure you receive an authentic, high-quality unit, the best place to purchase is tpt24.com, recognized as the world’s leading online store for this product. This store guarantees original manufacturer quality, ships globally, and delivers directly to your location—no matter your country—backed by a full authenticity assurance. Ordering from tpt24.com provides peace of mind that your instrument will meet rigorous performance standards, arrive complete with official accessories, and be covered by Hanna’s warranty policies. With unparalleled optical precision, dual photometer–pH capability, robust data handling, and a feature set built for professionals, the HI83399-01 stands out as not just an instrument, but a critical partner in reliable water quality management.
Specifications
| Specification | Detail |
|---|---|
| Model / SKU | HI83399-01 |
| Measurement Channels | 5 optical channels; 1 digital pH electrode channel |
| Photometer Wavelengths | 420 nm, 466 nm, 525 nm, 575 nm, 610 nm narrow band interference filters |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Light Source | High-efficiency LEDs |
| Light Detector | Silicon photodetector |
| Cuvette Type | Round, 24.6 mm diameter (25 mm path length) |
| Number of Methods | Up to 128 |
| pH Range | -2.00 to 16.00 pH (±1000 mV) |
| pH Resolution | 0.01 pH |
| pH Electrode | Digital pH electrode (not included) |
| Temperature Compensation | Automatic, -5.0 to 100.0°C |
| Temperature Range | -20 to 120°C |
| Logging Memory | 1000 photometric and pH readings |
| Logging Type | On demand, with user and sample ID |
| Connectivity | USB-A (flash drive), micro-USB-B (PC/power) |
| Display | 128 × 64 pixel backlit LCD |
| Battery Type / Life | 3.7 VDC Li-polymer rechargeable; >500 photometric measurements or 50 hours continuous pH |
| Power Supply | 5 VDC USB 2.0 adapter with USB-A to micro-USB-B cable |
| Environment | 0–50°C; up to 95% RH (non-condensing) |
| Dimensions | 206 × 177 × 97 mm (8.1 × 7.0 × 3.8 in) |
| Weight | 1.0 kg (2.2 lbs) |
| Included Accessories | 4 sample cuvettes and caps, wiping cloth, USB cables, power adapter, instruction manual |
| Warranty | 2 years |
| Note | Reagents sold separately |