Hanna HI93414-01 Turbidity and Chlorine Portable Meter
- Turbidity Range: 0.00 to 1000 NTU
- Chlorine Range: 0.00 to 5.00 mg/L
- Calibration Points: Two to four for turbidity
- Memory Records: Up to 200 readings
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Hanna HI93414: A Comprehensive Overview
The Hanna HI93414 is a state-of-the-art portable meter designed to provide accurate and reliable measurements of turbidity and chlorine, two of the most critical parameters for ensuring drinking water quality. This dual-functionality instrument combines a nephelometer for turbidity measurements and a photometer for chlorine analysis. The device’s advanced optical system is built around a tungsten filament lamp, along with a sophisticated arrangement of detectors and filters that work together to minimize external interferences, such as stray light and color, which can often skew readings. This precise engineering ensures that users can depend on the results for low turbidity and chlorine values, which is essential for compliance with strict regulatory standards.
Furthermore, the HI93414’s design incorporates features that make it highly adaptable and user-friendly for a variety of field and laboratory applications. Its ability to perform both turbidity and chlorine measurements in a single, portable unit streamlines the testing process, making it an indispensable tool for water quality professionals. The meter is also designed with several practical functions that enhance its utility, including multiple measurement modes (normal, continuous, and signal averaging) and a user-friendly, backlit LCD display that guides users through each step of operation. This combination of technical precision and practical functionality makes the HI93414 a powerful and versatile instrument for maintaining water quality and ensuring public safety.
Key Features of a Reliable Water Meter
The HI93414 stands out due to its impressive array of features that ensure both accuracy and ease of use. At its core, the device is designed to be fully compliant with the rigorous standards set by the USEPA and Standard Methods for both turbidity and colorimetric measurements. It offers a wide turbidity range from 0.00 to 1000 NTU and a chlorine range from 0.00 to 5.00 mg/L (ppm), making it suitable for diverse applications from pure water analysis to wastewater monitoring. The meter’s EPA compliance is further highlighted by a specific reading mode that automatically rounds turbidity results to meet official reporting requirements. This level of detail and adherence to regulatory guidelines provides a high degree of confidence in the data collected.
Moreover, the HI93414 incorporates the powerful CAL Check™ function, which allows users to validate the instrument’s performance at any time using exclusive, NIST-traceable standards. This feature, along with the device’s ability to perform two, three, or four-point turbidity calibrations, ensures that measurements remain accurate and consistent over time. For chlorine measurements, a one-point calibration is available. The device’s Good Laboratory Practice (GLP) functions also add a layer of traceability, allowing users to review the date, time, and calibration points of the last calibration with a simple touch of a button. These integrated quality assurance and control features are paramount for professional use, ensuring that every reading is trustworthy and verifiable.
Unlocking Data Management with Fast Tracker
For professionals working in the field, efficient data management is just as crucial as accurate measurement. The Hanna HI93414 addresses this need with its innovative Fast Tracker™ – Tag Identification System (T.I.S.). This system is designed to simplify the collection and organization of data, particularly in large-scale or multiple-location applications. It works by using unique iButton® tags, which are essentially computer chips encased in stainless steel. These tags can be installed near various sampling points, allowing users to quickly and easily log the time and location of each measurement simply by bringing the meter into contact with the tag. This eliminates the need for manual record-keeping and minimizes the risk of human error.
The Fast Tracker™ system significantly streamlines fieldwork and improves data integrity by linking each reading directly to its source location and time. The HI93414’s internal memory can store up to 200 tagged measurements, which can then be transferred to a PC for further analysis and archiving. Data transfer is made easy through both RS232 and USB interfaces, compatible with Hanna’s HI92000 software. This comprehensive data logging and transfer capability not only simplifies the day-to-day work of field technicians but also provides a robust, traceable dataset for reporting and long-term analysis.
The Crucial Role of Turbidity Measurement
Turbidity is a fundamental parameter for assessing the quality of drinking water and natural water sources. It refers to the haziness or cloudiness of a fluid caused by suspended particles. The HI93414 is expertly designed to measure this property, providing critical data for water treatment and quality control. Turbidity is a key indicator of water’s aesthetic quality, but more importantly, it serves as a reliable safeguard against pathogens. Pathogenic microorganisms, such as bacteria, viruses, and parasites, can attach to suspended solids, making them more difficult to remove through disinfection and filtration processes. By controlling turbidity, water treatment plants can effectively manage this risk.
The HI93414’s ability to measure turbidity in the 0.00 to 1000 NTU range makes it versatile enough for various applications. In drinking water treatment, it helps ensure that water from surface sources like lakes and rivers meets strict EPA reporting requirements. In natural water environments, turbidity measurements help gauge overall water quality and its suitability for aquatic life. Furthermore, in wastewater treatment, the meter is essential for verifying that discharge meets regulatory standards. The instrument’s optical system, which includes a tungsten filament lamp and multiple detectors, ensures that readings are accurate and compensate for potential interferences, providing a reliable basis for critical water quality decisions.
The Importance of Chlorine Analysis
Chlorine is another vital parameter measured by the HI93414, playing a crucial role in public health and water safety. As a powerful disinfectant, chlorine is widely used in drinking water treatment to eliminate harmful bacteria, viruses, and other pathogens. The HI93414’s photometer function accurately measures both free chlorine and total chlorine in the range of 0.00 to 5.00 mg/L (ppm). Free chlorine refers to the available chlorine that is ready to disinfect, while total chlorine includes both free and combined chlorine. Monitoring these levels is essential to ensure that there is enough residual chlorine in the water distribution system to prevent re-contamination.
The HI93414’s chlorine measurement method is an adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G, which are recognized as reliable and accurate procedures. The colorimeter part of the meter uses a 525 nm narrow band interference filter to ensure a precise wavelength for measurement. The reaction between chlorine and a DPD reagent causes a distinctive pink tint in the sample, which the meter then analyzes to determine the chlorine concentration. By providing a fast, accurate, and reliable way to measure chlorine, the HI93414 empowers water quality managers to maintain proper disinfection levels, protecting the public from waterborne diseases.
A Design Engineered for Precision
The Hanna HI93414 is built on a foundation of precision engineering to deliver highly accurate results. Its optical system is a key differentiator, featuring a tungsten filament lamp and a set of detectors that measure scattered and transmitted light. In the ratio turbidimeter range, the meter’s microprocessor uses an advanced algorithm to correct and compensate for color interferences, which can otherwise affect the accuracy of the reading. This intelligent compensation ensures that the results are reliable even with colored samples. The optical system also minimizes stray light to less than 0.02 NTU, which is crucial for achieving high accuracy in low turbidity measurements.
The device’s use of 25 mm round cuvettes, made from special optical glass, also contributes significantly to the repeatability and consistency of measurements for both turbidity and chlorine. These cuvettes are designed to maintain a consistent optical path, which is vital for accurate readings. The meter’s design, including the specific arrangement of its components, limits the need for frequent calibration by compensating for variations in the lamp’s intensity. This combination of robust hardware and smart software algorithms results in an instrument that is not only highly accurate but also stable and reliable over the long term, making it a valuable investment for any water quality program.
A Global Solution Delivered with Trust
In an increasingly interconnected world, having access to reliable, high-quality instruments is paramount, no matter where you are located. When it comes to the Hanna HI93414, the online store tpt24 stands out as the premier global retailer. They are widely recognized as the top online store for this product, delivering it with an unwavering commitment to authenticity and quality assurance to customers in any country. This global reach and dedication to customer satisfaction make purchasing a high-precision instrument like the HI93414 a seamless and trustworthy experience.
The partnership with a reputable seller like tpt24 ensures that customers receive the genuine product along with its complete set of accessories and documentation, including sample cuvettes, calibration cuvettes, silicone oil, batteries, and a rugged carrying case. This comprehensive package guarantees that users can get started with their measurements right away, with all the necessary tools at their disposal. The convenience and reliability offered by tpt24 make it the ideal choice for laboratories, field technicians, and organizations around the world seeking to acquire the Hanna HI93414 and benefit from its advanced capabilities for water quality analysis.
The HI93414’s Practical Applications
The versatility of the Hanna HI93414 makes it an essential tool across a wide range of practical applications. In public health, it is used by municipalities and water utilities to continuously monitor drinking water quality, ensuring that it meets regulatory standards for turbidity and disinfection. Its portability allows technicians to conduct on-site analysis at various points in the water distribution network, from treatment plants to consumer taps, providing real-time data that is critical for maintaining public safety.
In environmental science, researchers and monitoring agencies use the HI93414 to assess the health of rivers, lakes, and streams. By measuring turbidity, they can track sediment levels from runoff and pollution, which directly impacts aquatic ecosystems. The device is also vital for industrial processes that rely on water quality, such as in food and beverage production, where even small variations in turbidity or chlorine levels can affect product consistency and safety. In wastewater management, the HI93414 helps ensure that treated effluent is within legal limits before being discharged into the environment, preventing pollution and protecting natural habitats. These diverse applications highlight the meter’s role as a versatile and indispensable instrument for professionals across various sectors.














