Hanna HI88713-01 ISO 7027 Compliant Benchtop Turbidity Meter
- Measurement Range: 0.00 to 4000 NTU
- Light Source: Infrared LED
- Log Memory: 200 records
- Accuracy: 2% of reading plus stray light
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
An Introduction to the HI88713 Turbidity Meter
The Hanna HI88713-01 is a precision benchtop turbidity meter specifically engineered for water quality measurements. It is designed to provide highly reliable and accurate readings, even in liquids with very low turbidity. The core of this instrument is its advanced optical system, which guarantees precise results, ensures long-term stability, and effectively minimizes interference from stray light and color. To maintain its accuracy over time, the meter includes a calibration function that compensates for any fluctuations in the intensity of its infrared LED light source. The use of special optical glass in the 25 mm round cuvettes further guarantees the repeatability of measurements. The HI88713 fully complies with the ISO 7027 method, which uses an infrared light source, making it an ideal choice for professionals who require a dependable and standards-compliant instrument.
This sophisticated device is supplied with AMCO-AEPA-1 primary turbidity standards, which are recognized by the USEPA and are used for both calibration and performance verification. These non-toxic standards consist of uniform styrene divinylbenzene polymer spheres, offering excellent stability and a long shelf life, and they are reusable. The HI88713 provides several features that simplify the measurement process, including multiple reading modes like normal, continuous, and signal averaging. With its backlit graphic LCD display, the interface is user-friendly and easy to read, with all messages in plain text. The inclusion of a tutorial mode and a dedicated HELP button also makes it easier for users to perform setup and calibration correctly, ensuring accurate results every time.
Key Features for Exceptional Performance
The Hanna HI88713 is equipped with several key features that set it apart. One of its most notable attributes is the four distinct measurement modes: FNU, FAU, and both ratio and non-ratio NTU modes. This versatility allows the meter to handle a wide range of turbidity levels, from low-turbidity drinking water to highly turbid wastewater. For instance, the NTU ratio mode can measure up to 4000 NTU, while the FNU mode is designed for measurements up to 1000 FNU. Another significant feature is the ISO 7027 compliance, which is achieved through the use of an infrared LED light source. This specific light source is crucial as it eliminates color interference in the sample, ensuring more accurate turbidity readings compared to methods that use visible light.
The meter also features a powerful calibration function that allows for two, three, four, or five-point calibration using the supplied standards. This flexibility ensures that the instrument can be precisely calibrated for a variety of applications and measurement ranges. Additionally, users have the option to use their own standards, and the calibration points can be modified accordingly. The GLP (Good Laboratory Practice) function is another valuable feature, providing complete traceability of calibration conditions, including the specific calibration points, date, and time. This is particularly important for quality assurance and regulatory compliance in professional laboratory settings. The meter’s ability to log up to 200 measurements and transfer them to a PC via USB for further analysis highlights its modern design and suitability for detailed data management.
Operational Principles and Advanced Technology
The operation of the HI88713 is based on sophisticated optical principles that utilize both scattered and transmitted light to determine turbidity. When a light beam from the infrared LED passes through a liquid sample, it is scattered in various directions by suspended particles. The meter’s optical system is comprised of two key detectors: a scattered light detector positioned at a 90° angle and a transmitted light detector at a 180° angle. The specific measurement mode determines which of these detectors is used to calculate the final turbidity value. For example, in non-ratio modes (FNU and NTU), the turbidity value is calculated solely from the signal received by the 90° scattered light detector.
In contrast, the ratio turbidimeter mode utilizes signals from both the scattered and transmitted light detectors. An advanced microprocessor within the meter uses an effective algorithm to process these signals, allowing it to correct for and compensate for any color-related interferences. This dual-detector approach results in higher accuracy, especially in highly turbid samples. One of the most critical factors in a turbidimeter’s performance is its stray light, which can cause inaccurate readings in low-turbidity samples. The HI88713’s optical system is meticulously designed to minimize stray light to less than 0.1 NTU (0.05 EBC), ensuring highly accurate and reliable results even in very clear samples. The use of AMCO AEPA-1 standards, which are NIST-traceable, guarantees that the meter’s measurements are precise and reliable, upholding the highest standards of quality and traceability.
Wide-Ranging Applications for Diverse Industries
The versatility of the Hanna HI88713 makes it an indispensable tool across numerous industries and applications. A primary use for this meter is in drinking water quality assessment. Turbidity is a key indicator of water purity, and controlling it is a vital safeguard against pathogens. The meter’s ability to provide accurate readings in low turbidity ranges makes it perfectly suited for monitoring treated drinking water, ensuring it meets safety standards. Another crucial application is in wastewater treatment plants. Historically, turbidity was a primary parameter for monitoring wastewater; today, it is essential for verifying that treated wastewater values fall within regulatory standards before it is discharged. The HI88713’s high-range measurement capabilities (up to 4000 NTU) make it ideal for this purpose.
The meter is also widely used in environmental monitoring, where turbidity measurements help gauge the general quality of natural water bodies like rivers, lakes, and streams. This is important for assessing the health of aquatic ecosystems and their compatibility with various aquatic organisms. For industries such as food and beverage production and pharmaceutical manufacturing, turbidity is a critical quality control parameter. The HI88713 can be used to monitor the clarity of products like beer, fruit juices, and syrups, or to ensure the purity of solutions used in drug manufacturing. Its ISO 7027 compliance and color interference compensation make it especially valuable in these sectors, where the color of the sample could otherwise affect the accuracy of measurements.
Ease of Use for Both Experts and Novices
Hanna Instruments designed the HI88713 with a strong emphasis on user-friendliness, making it accessible to both experienced professionals and those new to turbidity measurements. The meter’s backlit graphic LCD display is a central component of its user-friendly interface. All messages are displayed in plain text, eliminating the need to decipher cryptic codes or symbols. This clarity makes it easy for users to navigate menus, select settings, and understand measurement results at a glance. The display also shows the current measurement, time, and reading mode, providing all necessary information on a single screen.
The tutorial mode is a standout feature for new users. When enabled, the meter provides step-by-step guidance for key operations like preparing a sample or performing a calibration. It displays clear, on-screen explanations and includes a confirmation button to ensure the user performs each step correctly before proceeding. For more experienced users or those who need quick reminders, the dedicated HELP button offers contextual assistance. The help information displayed is relevant to the specific menu or setting the user is currently viewing, providing targeted guidance without having to consult a manual. This combination of a clear display, tutorial mode, and contextual help ensures that users can operate the HI88713 efficiently and confidently, minimizing the potential for errors.
Seamless Data Management and Transfer
In modern laboratory and industrial settings, efficient data management is just as important as accurate measurements. The HI88713 addresses this need with its robust data logging and transfer capabilities. The meter can store up to 200 measurement records in its internal memory, allowing users to save data points over time for later analysis. Each record is stored with important information, including the date, time, and measurement mode, ensuring complete traceability. This feature is particularly useful for field work or situations where immediate data transfer is not possible.
For long-term storage, detailed analysis, and report generation, the meter provides a USB serial interface. This allows for a seamless connection to a Windows-compatible PC. Using the HI92000 software, users can download the logged data, which is crucial for trend analysis, quality control documentation, and regulatory reporting. The ability to easily transfer data helps streamline workflows and reduces the risk of manual data entry errors. The combination of internal memory and PC connectivity ensures that all measurement data is securely stored and accessible, empowering users to maintain comprehensive records and make informed decisions based on their findings.
Why Choose the HI88713? A Definitive Choice
The Hanna HI88713-01 is more than just a turbidity meter; it is a comprehensive solution for precision water quality analysis. Its compliance with the ISO 7027 method, which uses an infrared light source, provides a significant advantage by eliminating the common problem of color interference that plagues meters using visible light. The instrument’s use of an advanced optical system with both 90° and 180° detectors, along with a sophisticated microprocessor, ensures the highest level of accuracy and stability, even in challenging samples. The availability of multiple measurement ranges and modes, from FNU to FAU and NTU, further enhances its versatility for different applications.
Beyond its technical specifications, the HI88713 is designed for practical use. The inclusion of AMCO AEPA-1 primary standards, which are reusable and have a long shelf life, simplifies calibration and ensures measurement traceability. Features like the tutorial mode, contextual help, and a clear graphic display make the instrument approachable for a wide range of users, reducing the learning curve and improving operational efficiency. The robust data logging and transfer capabilities are essential for modern quality control, enabling users to maintain detailed records and perform thorough data analysis. When you need a reliable, accurate, and user-friendly turbidity meter, the Hanna HI88713-01 stands out as a superior choice.
Exclusive Offering from tpt24
The best way to acquire the Hanna HI88713-01 ISO 7027 Compliant Benchtop Turbidity Meter is through the online store tpt24, which is the world’s leading online store for this product. Tpt24 guarantees the authenticity and quality of every unit, ensuring that you receive a genuine product that meets all international standards. The store is committed to delivering the meter with full warranty and quality assurance, regardless of your location. Tpt24’s efficient and reliable global delivery network ensures that your product will be delivered directly to you, no matter what country you are in. When you purchase from tpt24, you can be confident that you are receiving a high-quality, authentic product backed by a commitment to customer satisfaction.
Specifications