ICMflex: Advanced On-Site Partial Discharge Testing
The Megger ICMflex is a state-of-the-art, multifunctional instrument, redefining how engineers approach insulation diagnostics in high voltage (HV) assets. Designed to streamline complex measurement tasks, the ICMflex consolidates partial discharge (PD) detection, PD fault location on cables, and loss factor (tan delta) measurements into a single, versatile platform. Unlike conventional tools that rely on multiple instruments and intricate setups, ICMflex enables users to perform several essential high-voltage measurements conveniently and efficiently. With a robust modular design, it meets the rigorous needs of maintenance teams, service groups, laboratories, and manufacturers—whether the environment is a bustling workshop or a remote field location. Its integration of advanced safety features, operational simplicity, and minimized testing times set new standards for flexible, reliable diagnostics, providing a deeper insight into the insulation condition of critical electrical equipment.
Seamlessly Supporting Diverse High Voltage Applications
ICMflex is purpose-built for flexibility across a wide spectrum of HV applications, ensuring exceptional relevance for both field and laboratory settings. Service teams engaged in testing motors, generators, cables, accessories (terminations and joints), and rotating machines benefit from the unit’s multi-diagnostic capability. Manufacturers and research facilities leverage ICMflex for factory acceptance testing and R&D analyses, while maintenance and repair shops depend on its portability and rapid setup for efficient decision-making. By supporting partial discharge measurements per IEC 60270, power factor and tan delta assessments, and precise PD fault location for power cables, the ICMflex stands as an indispensable asset for HV cable testing, rotating machine evaluation, and even stator bar and single bar diagnostics. Its architecture guarantees compatibility with any fixed or portable high-voltage power source, from transformers and VLF systems to resonant test setups, enhancing its utility for utility engineers worldwide.
Reliable Measurements: Maximizing Operator Safety Levels
A defining strength of the Megger ICMflex is its rigorous approach to operator safety and measurement reliability. The acquisition hardware itself is positioned directly at high voltage potential—right at the origin of the PD signals—remarkably eliminating the need for long signal cables subject to interference. This not only boosts precision and sensitivity but also minimizes user exposure to hazardous areas. The design further reduces both testing duration and operational risk, reinforced by quick operational readiness and a user-friendly configuration. Effective noise suppression techniques are integrated within the device architecture, helping users capture even the faintest signatures of insulation degradation. Additionally, features like fibre optic gating inputs for noise reduction, certified calibration generators, and robust transportation cases furnish extra layers of measurement reliability and practical safety—making the ICMflex uniquely prepared for challenging on-site or industrial environments.
Modular Measurement Capabilities with Software Integration
What truly distinguishes the ICMflex is its modularity, enabling users to tailor the instrument to specific project demands. With remote-control capabilities via Bluetooth or fibre optic connections, users can control, configure, and monitor measurements from a safe or distant location using the intuitive ICMflex software platform. This software interface brings together all measurement data on a comprehensive dashboard, with three principal modes: PD (displaying phase-resolved discharge patterns and all relevant signals), LOC (dedicated to PD fault location with real-time cable fault positioning), and REC (tracking all measured values during standardized test sequences). Each mode supports in-depth analyses, reporting, calibration, and data export, delivering an all-in-one workflow perfectly suited to modern HV diagnostics. The software’s step-by-step guide further demystifies testing procedures, providing seamless walk-throughs for both experienced engineers and new users, and ensuring no critical step is overlooked.
Dedicated Accessories for Specialized Measurement Scenarios
For optimal performance and full measurement coverage, the ICMflex system can be complemented with a suite of well-engineered accessories. These include high voltage T-filters, which suppress high-frequency disturbance signals from external HV supplies and improve data integrity, and high frequency current transformers for precision PD capture. Other accessories, like the Gate Signal Transmitter GST1 (for remote noise gating), DAkkS-certified calibration impulse generators, and ready-to-use remote control computers preloaded with ICMflex software, collectively enhance the system’s adaptability. Convenient, rugged transportation cases offer mobility and resilience for field deployments. Through this modular accessory ecosystem, the ICMflex adapts to every unique testing situation—be it factory, laboratory, or live-field cable fault diagnostics—giving asset managers and engineers the freedom to structure their toolkits around every application’s specific needs.
Real-World Benefits for Maintenance and Diagnostics
By providing simultaneous PD detection, tan delta measurements, and PD fault locating—all orchestrated through a single, remotely controlled unit—the ICMflex yields unparalleled workflow efficiencies. Maintenance teams appreciate its ability to minimize inspection times, reduce downtime, and deliver actionable insights into insulation health without repetitive reconfigurations or redundant equipment. The ICMflex is commonly deployed for routine screening of aging cables, post-repair verification on HV joints and terminations, pre-commissioning assessment of new installations, and critical troubleshooting during unexpected outages. The instrument’s high precision, paired with its reliable detection of minute discharge events and clear fault localization capabilities (with up to 1-meter accuracy), ensures essential maintenance and asset management tasks are executed with maximum clarity and control.
tpt24: Trusted Source for Global Procurement
For customers worldwide seeking the Megger ICMflex, tpt24 stands as the premier online store for this advanced diagnostic system. tpt24 guarantees 100% authenticity, uncompromised quality assurance, and secure international shipping to any destination. Their expert team supports you from pre-purchase through post-installation, ensuring your ICMflex arrives ready for immediate deployment—backed by all manufacturer warranties and robust after-sales guidance. Whether you are a utility operator, testing service provider, or asset management specialist, choosing tpt24 means investing in a trusted partnership with the highest standards of reliability in the online marketplace. Wherever you are in the world, tpt24 delivers the Megger ICMflex hassle-free, providing unrivaled peace of mind for your diagnostic and asset management operations.
Specifications
| Parameter / Function | Specification / Details |
|---|---|
| Instrument Power Supply | Battery operated, up to 6 hours operation |
| Power Consumption | Approximately 20 VA |
| Operation | Remote via ICMflex software (Bluetooth/fibre optic) |
| PD Input Impedance | 1 kΩ |
| PD Input Sensitivity | < 150 µV (corresponds to 0.2 pC, no test object) |
| PD Lower Cut-Off (-6 dB) | 40, 80, or 100 kHz (software set) |
| PD Upper Cut-Off (-6 dB) | 250, 600, or 800 kHz (software set) |
| PD A/D Converter Resolution | 8 bits (±7 bits) |
| Voltage Measurement Resolution | 16 bits, 100 kSamples |
| Measured Voltage Values | U RMS, Ū/√2, Crest Factor |
| Synchronization | On reference voltage, 20–510 Hz (normal), also VLF |
| Operation Temperature Range | 0–55°C (non-condensing) |
| Interfaces | Bluetooth (921 kbit/s), Fibre optic (921 kbit/s) |
| Cable Fault Location A/D | 8 bits, 100 MSamples |
| Cable Length Measured | Min 10 m to max 25,000 m (up to 3000 m localization) |
| Cable Fault Loc. Precision | 1 m + 0.1% of cable length |
| Tan Delta Resolution | 5 × 10⁻⁵ |
| Tan Delta Precision | 1 × 10⁻⁴ |
| Environmental Compliance | ISO 9001, ISO 14001, ISO 17025, ISO 4501 |
| Accessories (Selected) | High voltage T-filters, current transformers, GST1, calibration generator, remote computer, cases |
| Product Code (Basic Unit) | PX10600 |