  • AccuracyHigh performance, high accuracy.

  • SafetyExida SIL 2 / SIL 3 Certified.

  • Max Cable Length45 meters maximum distance.

  • Signal OutputStandard 4-20 mA output.

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Category:
Brand:

Description

Yokogawa Digital Remote Sensor Revolutionizes DP Measurement

The introduction of the Yokogawa EJXC40A Digital Remote Sensor (DRS) Transmitter marks a significant paradigm shift in the field of process measurement, specifically for demanding Differential Pressure (DP) applications. Traditional DP measurement systems, particularly those employing long capillary lines for remote diaphragm seals, have historically been plagued by issues related to temperature fluctuation, fluid density changes within the capillaries, and complex, time-consuming calibration procedures. The EJXC40A directly addresses these fundamental shortcomings by integrating high-precision digital communication directly between the primary sensing element and the transmitter body. This ingenious architecture leverages a dedicated, robust DRS communication cable, ensuring that the crucial pressure signal is transmitted digitally, immune to the environmental noise and thermal effects that compromise analog signals. By maintaining the integrity of the measurement across potentially significant distances, the EJXC40A guarantees superior stability and accuracy for complex flow, level, and pressure monitoring tasks across critical industrial sectors. This digital backbone facilitates not only unprecedented reliability but also streamlined maintenance, dramatically reducing the lifecycle cost associated with traditional DP installations where filling solutions and compensation errors frequently introduce systemic errors. The core innovation lies in decoupling the measurement electronics from the harsh process interface while maintaining high-speed, deterministic data transfer, thereby setting a new benchmark for remote sensing integrity.

Superior Performance For Complex Flow Measurement Applications

The EJXC40A is engineered to excel in the highly challenging environment of fluid flow measurement, whether dealing with liquids, gases, or steam. In flow applications, accurate DP measurement is directly proportional to the square root of the flow rate, meaning any instability or inaccuracy in the DP reading is severely magnified downstream. By utilizing the DRS system, the primary sensor, which is subjected directly to the process conditions, captures the raw DP signal digitally. This digitized measurement bypasses the need for capillary tubes filled with silicone oil or inert fluids, eliminating the notorious “damping” effect and temperature-induced errors associated with these traditional interfaces. For gas and steam flow measurement, where process temperatures can vary widely, the EJXC40A maintains exceptional measurement fidelity. The standard transmitter configuration allows for the configuration of square root extraction directly within the device, utilizing the highly accurate digital input to produce a linearized 4-20 mA output that precisely reflects the volumetric or mass flow rate. This level of consistency is vital for custody transfer and precise process control loops where deviations can lead to significant material losses or product quality degradation. The inherent speed of the digital communication allows the transmitter to respond almost instantaneously to process changes, offering superior transient response compared to systems reliant on slow-moving analog fluid columns.

Revolutionizing Liquid Level Measurement In Tall Tanks

One of the most transformative capabilities of the Yokogawa EJXC40A lies in its ability to handle extreme elevation differences inherent in measuring liquid levels in very tall tanks, a scenario that cripples conventional DP systems. In a standard remote seal setup measuring liquid level, the hydrostatic head exerted by the fluid column in the long capillary line must be meticulously compensated for; if the impulse line temperature changes, the density of the fill fluid shifts, creating a persistent measurement error that is often larger than the actual process pressure change. The EJXC40A’s DRS technology negates this dependency entirely. The secondary sensor, positioned at the high-pressure tap, and the primary sensor, positioned at the low-pressure tap, communicate their measurements digitally to the transmitter body, which may be located far from the tank. Crucially, the EJXC40A supports a massive maximum DRS cable length of up to 45 meters. This extended reach allows operators to place the transmitter body safely in an accessible location—away from corrosive fumes or extreme heat—while accurately measuring levels in tanks reaching depths of 45 meters or more. The intrinsic immunity to temperature variations along the cable path ensures that the calculated level, derived from the highly accurate digital differential measurement, remains perfectly calibrated against the true liquid height.

Unmatched Versatility Across Diverse Pressure Ranges

The modular design philosophy of the EJXC40A is further enhanced by a comprehensive selection of interchangeable primary sensing capsules, providing an extraordinary range of applicability across the entire spectrum of industrial pressures. By simply swapping the primary sensor unit (the secondary sensor remains the primary measurement point relative to the process), users can adapt the transmitter for nearly any application requirement without recalibrating the entire electronic system significantly. This modularity saves significant time and reduces inventory complexity. The following table clearly outlines the available capsule options, demonstrating the instrument’s adaptability from low-range DP to extreme high-pressure monitoring:

Capsule DesignationMeasurement RangeApplication SuitabilityA2 to 200 kPaLow DP, Flow, LevelB0.01 to 2 MPaMedium DP, Liquid LevelC0.05 to 10 MPaHigh Pressure, Gas FlowD0.35 to 50 MPaVery High Pressure Monitoring

This rangeability, combined with the digital accuracy afforded by the DRS architecture, means that a single platform can support a plant’s entire spectrum of DP requirements, ensuring consistent operational philosophies and data formats across disparate systems, leading to enhanced cross-training benefits for maintenance personnel.

Advanced Signal Characterization For Complex Geometries

Beyond simple linear DP measurements, the EJXC40A incorporates sophisticated on-board processing capabilities essential for accurately characterizing non-linear or complex process conditions. Signal Characterization is a powerful feature that allows the transmitter to digitally linearize the output signal to match the specific physical profile of the vessel or primary element being measured. For liquid level measurements, this is crucial when dealing with non-cylindrical tanks, such as those with conical bottoms, spherical sections, or complex internals (e.g., heat exchanger bundles taking up volume). The system can be programmed with the tank’s geometric data, enabling the transmitter to take the raw, pressure-derived level information and mathematically convert it into a true volume reading (e.g., Gallons or Liters), rather than just a percentage of height. This eliminates the need for external programmable logic controllers (PLCs) or computers to perform these linearization calculations, simplifying the control architecture and reducing potential sources of error. Furthermore, the digital nature of the signal path ensures that these complex calculations are performed with the highest fidelity, maintaining the inherent accuracy of the sensor capsule throughout the linearization process, a significant advantage over analog signal processing methods.

Ensuring Process Safety Through High Integrity Design

Safety is paramount in modern industrial instrumentation, and the Yokogawa EJXC40A is built upon a foundation of rigorous design standards and verifiable performance metrics. The transmitter boasts Exida SIL 2 / SIL 3 Certification, validating its suitability for deployment in Safety Instrumented Systems (SIS) where measurement failure could lead to catastrophic consequences. This certification is not merely a label; it reflects a comprehensive evaluation of failure modes, diagnostic coverage, and overall probability of failure on demand (PFD). By integrating high-integrity digital communication and robust sensor technology, the EJXC40A provides the reliability demanded by high-risk operations, such as critical pressure protection or emergency shutdown loops. The inherent self-diagnostics capabilities of the digital platform constantly monitor the health of the primary sensor, the integrity of the DRS cable, and the internal electronics, flagging potential degradation long before it impacts the process control or safety function. This proactive monitoring significantly enhances plant uptime and reduces unexpected shutdowns caused by instrumentation drift or failure.

Specifications

Capsule Measurement Span Range
A 2 to 200 kPa −200 to 200 kPa
B 0.01 to 2 MPa −2 to 2 MPa
C 0.05 to 10 MPa −10 to 10 MPa
D 0.35 to 50 MPa −50 to 50 MPa